21/ 53
Commissioning/switching on
Power supply
For power supply, a corresponding battery must be connected to the MPX socket (bottom right).
Recommended batteries:
3s/LiPo 2500-5500mAh
4s/LiFePo4 2500-5000mAh
The battery type is defined in the System-Settings (also see page: 30) and may need to be adjusted.
By default, the system is preset to a 3s LiPo battery.
The battery is preferably attached to the bottom of the fuel station with Velcro® straps.
The effective battery type can be set in System-Settings (p. 30)
To charge the battery, be sure to remove it from the fuel station!
When storing the fuel tank with the fuel station attached, remove the battery for safety reasons! The
system has no polarity reversal protection, reversing the polarity of the supply battery will destroy the
electronics!
Switching on/off
Switch on by briefly pressing the
I
Stop
key.
Switch off by pressing and holding the
I
Stop
key for at least 1.5 seconds.
During this time, a "countdown" will appear in the display, if the key is released before the countdown,
the system remains switched on!
Immediately after switching on, the display shows the following information for 2 seconds:
Here the version number is displayed
Here the container name is displayed (p.40)