34/ 53
Statistics menu
Parameter Name
Description
Total Run-Time
Total running time of the pump
TotalFuel pumped
Total conveyed amount
No of fills
Number of fills
No of drains
Number of emptying operations
LoBatt counts
Number of undervoltage trips
Scroll between the different parameters with the
key.
The values are only for display/information and cannot be changed.
Tables with key commands
Before starting a filling or emptying process, the hose connections must be made properly!
Also, make sure that the correct model with the appropriate fill mode has been selected!
For example, if a bag tank is in the model to be refueled and is falsely refueled with a program for
normal tanks using the flowback line, this may cause the bag tank to rupture because in this mode of
operation, no analysis of the flow to terminate refueling occurs! See also the Burst Protection parameter
in the System-Settings.
In order to give the user an acoustic feedback, which tank type is selected, an acoustic signal is always
given when starting the refueling process, which characterizes the shut-off signal used for "tank full"
detection:
One beep: shutdown via flow detection active, i.e. flowback line does not have to be connected.
Three beeps: Shutdown via flowback line active, i.e. flowback line must be connected!