Failsafe delay
Setting for the period before the ECU will go into the Failsafe
mode and reduce the throttle to the preset
FailSafeRPM
. After
the
FailSafeTimeOut
below, the engine would then shut off.
This maybe programmed from 0.1 to 20 seconds (Default = 0.1 seconds).
Failsafe Delay
:0.1
Failsafe timeout
Setting for how long the turbine will run in a failsafe condition
before the engine shuts off. This may be programmed from 0.1
to 20 seconds (Default = 2 seconds).
FailSafeTimeOut
:2.0
Failsafe RPM
Setting for the RPM the engine will run at durring the
FailSafeTimeOut
. This maybe programmed from Minimum
RPM to Maximum RPM (Default = Minimum RPM).
FailSafeRPM
:33000
If the engine is shutdown because of a failsafe, in the
Info Menu
the
LAST-OffCond
:FailSafe
will be displayed. The
Info Menu
has selections for
LastFailsafeCnt:0
and
Last FailSafeTim:0.0.
This is the number of times the ECU went into failsafe and the
actual time period it was in failsafe during the last flight.
How to set your ECU for single channel operation
NEW FOR ECU V4.9R and later!
Single channel operation can be done automatically by not connecting the auxiliary
channel to the receiver. When you are in the Learn-R/C mode, it will detect the auxiliary
channel is not plugged in and will automatically change to single channel operation.
One or two receiver channels may be used to control the JetCat ECU. If single channel
is desired, follow these steps.
•
Plug in the GSU and power up the system.
•
Press the limits key.
•
Using
the
►
+ key, scroll through the selections until AUX-channel func is
displayed.
•
There are three selections in the AUX-channel func menu. While pressing the
Change Value key, use the
◄
- or
►
+ key to scroll through these selections.
Page 31/74