The R/C Check Menu
All parameters in this menu are for informational purposes only and will vary in
accordance with R/C input.
Value
Explanation
StickPuls
Throttle%
Position of the throttle stick (by percentage, 0-100%). An ‘F’ signals
a failsafe condition.
Position units of the throttle stick.
FailSafe Count
Displays the number of times the receiver went into failsafe during
the flight.
FailSafeTime
In seconds
Displays the time the receiver was in failsafe.
The INFO Menu
Info menu displays the following information:
Value
Explanation
BattCnd
Ubattery
The condition of the battery is indicated in the upper line:
1.
--OK--
2.
!WEAK!
3. --EMPTY--
1. If the battery voltage is 1.1V/Cell or higher “
—OK--
“ will be
displayed.
2. If the battery voltage drops under 1.1V/Cell, the display will
read “
!WEAK!”
. Red
Standby
and green
OK
LED’s will blink
simultaneously (at a rate of twice per second). Starting the
turbine is not possible, until the battery is recharged. If the
turbine is already running and the battery warning function is
enabled, the warning function will be activated.
3. If the battery voltage drops under 1.0V/Cell “—
EMPTY--
”
is
displayed. Starting the turbine is not possible until the battery
is recharged. If the turbine is running, it will be immediately
shut off, to avoid a malfunction of the ECU.
Current voltage of the battery. Displayed on bottom line.
Last Run Time
Last turbine run time.
Last-Off PmpVolt
Volts applied to the pump when it was switched off.
Last Off RPM
RPM of the turbine, when it was switched off.
Last Off TEMP
Temperature of the turbine, when it was switched off.
47