Page 12

WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE
APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES.

WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF
AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A
COMPLIANCE PLATE WITH THE MARKING ‘TESTED TO AS/NZS 4013’.

ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS
CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013.

CAUTION: MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL
SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE
MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE.

CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED WITH CRACKED AND BROKEN COMPONENTS, e.g. GLASS PANELS OR
CERAMIC TILES, MAY RENDER THE INSTALLATION UNSAFE.

WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING
AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE.

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN ITS OPERATING.

WARNING: DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES.

WARNING: OPEN AIR CONTROLS AND DAMPER WHEN FITTED BEFORE OPENING FIRING DOOR.

WARNING: FOR OPTIMUM PERFORMANCE FUEL MUST BE LOADED SO THE LOGS LAY “FRONT TO REAR” IN PREFERENCE TO
LAYING ACROSS THE WIDTH OF THE FIREBOX. SPACES SHOULD BE LEFT BETWEEN THE LOGS TO ENABLE OXYGEN TO GET
TO AS MUCH OF THE SURFACE OF THE FUEL AS POSSIBLE.

CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS.

CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE HAZARDOUS.

AS/NZS 2918 General notes

Fuels

The quality of firewood is extremely important. How long a tree
has been felled or dead for does not indicate how dry the wood
is.
The best way to dry wood is to split it and expose the inner core
allowing the sun to dry the wood naturally.
Good wood merchants will split the wood for you, but may not
season it for you.
The amount of you pay for your wood does not justify how dry
the wood is. The only way to know how dry your wood is, is to
use a moisture meter measuring from the inner core of the
wood.

Only burn wood under 20% moisture. Anything over 20% and
your wood heater will not work efficiently. The energy from the
fire will be used to reduce moisture in your wood and not
produce heat for your house.
Store your wood for at least 12 months after your have
purchased it. Your wood should be at a perfect moisture level, of
around 15 to 20%. Never burn treated wood or painted wood.

Cleaning

The Jetmaster Log Pan is designed to give greater heat and fuel
efficiency. For the duration of the cold season the Log Pan
should never be emptied. The resulting bed of ash and coals
from previous fires will soon become a heat bank generating
more heat than the burning logs. This ash bed also insulates and
greatly extends the life of the Log Pan. This is why an ash bed
must be maintained at all times.

When the level of the ash bed becomes too high, the top layer
can be removed. Depending on frequency of use and quality of
wood, this skimming procedure should not be required more
than once or twice a Season!

To prevent chimney fires as well as enabling the chimney to
draw properly, the chimney/flue should be swept at least once a
season,subject to the quality of timber used in the fire.

General Maintenance

The visible parts of your Jetmaster can be cleaned with a damp
cloth or soft brush. Should you wish you could repaint the unit
with a heat resistant paint?

Safety

The Jetmaster is a safety-tested unit, however, you must never
leave an open fire unguarded. Jetmaster has a screen that is
designed to prevent sparks leaving the fireplace and very
resistant to being accidentally knocked over by young children.

Summary of Contents for 1200 series

Page 1: ...only Other fuels may over fire and generate poisonous gases i e carbon monoxide Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not...

Page 2: ...11 6 General use Attaching firescreen lighting a fire 12 6 General use Fuels Cleaning Maintenance Safety 12 AS NZS 2918 2018 General notes Thank you for purchasing a Jetmaster fireplace Please read th...

Page 3: ...is with height of chimney minimum 4 6 metres as per AS NZS 2918 2018 C Negative Pressure Negative pressure results from the imbalance of air available for the appliance to operate properly It can be...

Page 4: ...flow of outdoor air for all combustion appliances and exhaust equipment Ensure cental heating and air conditioning return vents are not located in the vicinity of the appliance Avoid installing the a...

Page 5: ...1500 dual spigot gather 1550 1600 600 1000 400 300 350 450 150 Measurements are in mm and provided as a reference only Double flue size is 50mm bigger than the above F measurements Dual spigot will r...

Page 6: ...plications an AGA approved cowl must be used C D Measurements are in mm and provided as a reference only Due to the nature of thick welded steel it is normal and expected for some imperfections and sl...

Page 7: ...GOT 1600 1730 750 1500 DOUBLE SPIGOT 1600 1730 690 Note Timber framing should be constructed using normal framing methods Image above is an example only Do not install finishing materials around the c...

Page 8: ...ce see joint AS NZS 2918 2018 3 3 2 The floor protector should extend 900mm in front of the appliance opening and be placed centrally in the 1650mm width 100mm thick floor protector projection can con...

Page 9: ...op of the appliance gather with 100mm R3 5 insulation compressed to 15mm between the appliance and Hebel PowerPanel Double spigot gather is narrower It is important to ensure Hebel cavity is within 15...

Page 10: ...ation cap away from trees adjacent structures uneven roof lines and other obstructions Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions th...

Page 11: ...crimp facing up to ensure water penetration on flue above roof runs out Rivet active flues together at crimped joins Fix outer non active flues to active inner flues use 3 x 25mm self tapping screws...

Page 12: ...side towards you with the steel handle provided 2 In firebox lay your fire lighters 10 to 15 centimetres apart depending on the size of your firebox Do not use newspaper as a fire lighter On units th...

Page 13: ...S NZS 2918 General notes Fuels The quality of firewood is extremely important How long a tree has been felled or dead for does not indicate how dry the wood is The best way to dry wood is to split it...