Installation & Operation manual of Jetmaster Vent Free range
Page 4
Revision 01/09
TECHNICAL DATA
DIMENSIONS
MODEL
W
H
L
700 BI M
795mm
325mm
610mm
All dimensions in mm
GAS SPECIFICATIONS
MODEL
GAS
CONSUMPTION
Max rate
GAS
CONSUMTION
Min rate
injector
Gas supply
pressure
700 BI
36 MJ/hour
10 kW
0.7 kg/h
20 MJ/hour
5.6 kW
0.4 kg/h
1.3mm
#1
2.8 kPa
#1 – The appliance must be installed using an appropriate regulator that can maintain the operating gas
supply pressure during use and that complies with the requirements of SANS 1237.
NOTE:
We suggest that you check the Data Plate on your Gas Burner and verify the Model on the above table, for future
reference.
WARNINGS
•
Do not place articles on or against this appliance
•
Do not use or store flammable materials near this appliance
•
Do not spray aerosols in the vicinity of this appliance while it is in operation
•
These units incorporates a live fuel effect and is designed to burn with luminous flames and as such may
exhibit slight carbon deposits (soot)