Deluxe Control Programming
F/12 Hour
C/24 Hour
Press
OFF
and
to change
TO SET CURRENT TIME
Press
and
until it
fl
ashes
Press
to set hour
Press
to set minute
TEMP and TIMER modes
-Press SET until
✴
/ TEMP is displayed. Press and hold SET until the degree display
fl
ashes.
-Set temperature for
✴
using up or down arrows. Press SET to save. Repeat process for
/TEMP.
-Press SET until TIMER is displayed. Press and hold SET until the time display
fl
ashes. Adjust the hour with the up arrow and the
minutes with the down arrow. Press SET to advance to the next cycle time. Once all four times are set, press OFF.
Upon pressing the OFF button the remote will default to MAN (manual) mode.
-If you leave in the MAN mode unit will only function manually. Pilot lit only when
fi
replace is operating.
Starting the
fi
re, refer Diagram 1:
• Press spark symbol and up arrow simultaneously
• Receiver will beep indicating remote signal has been
received (you can then release the buttons)
• System will continue beeping once every second
(approximately 6-8 seconds) until ignition sequence
is complete and
fi
re is alight
• The
fi
re will always light on high
fl
ame
• To turn off
fi
re press off button only
MANUAL FLAME ADJUSTMENT
Use large buttons
Operation: Deluxe Remote Control (REM-DLX-CE)
Diagram 1
OPERATION
In TEMP mode:
-Turn
fi
replace ON.
-Press SET until
✴
/ TEMP appears - the
fi
replace will maintain the
✴
temperature 24 hours/day.
or
-Press SET until
/ TEMP appears - the
fi
replace will maintain the
temperature 24 hours/day.
(When in either
✴
or
TEMP mode, the remote will turn the
fi
replace on and off to maintain the set temperature. Pilot stays lit at all
times in TEMP mode.)
In TIMER mode:
-Turn
fi
replace ON.
-Press SET until the TIMER appears. In TIMER mode the remote will turn the
fi
replace on and off during the set times (to maintain the
✴
and
temperatures set in TEMP mode).
______________________________________________________________________________________________________________
Description of operation in TIMER mode:
-In TIMER mode, you are effectively setting four time periods for Thermostat operation, two periods at the
✴
temperature and two
periods at the
temperature
If
✴
is set at 22 and
is set at 17, and the TIMER settings are as shown:
P1
✴
06:00 P1
08:00 P2
✴
16:00 P2
20:00
The
fi
replace will maintain a temperature of 22 during the
✴
time settings- from 06:00 until 08:00
and
from 16:00 until 20:00. A
temperature of 17 will be maintained during the
time periods- from 08:00 until16:00
and
20:00 until 06:00.
If the
temperature is set below 5 degrees, the
fi
replace will stay in stand-by mode (pilot only) until the next
✴
cycle.
Description of
fl
ame modulation operating in TEMP mode or TIMER mode:
If room temperature is 3 or more degrees below the set temperature, the
fi
replace will light on high
fl
ame. When room temperature
is within 2 degrees of the set temperature,
fl
ame will lower. When room temperature is within 1 degree of the set temperature,
fl
ame
will adjust to the lowest setting. When set temperature is reached, the
fi
replace will turn off. If the room cools more than 1.5 degrees
below set temperature, the
fi
replace will light (on medium to low
fl
ame).
The remote sends a signal to the
fi
replace when operating in TEMP or TIMER mode every 2 minutes. If during this 2 minute cycle
someone opened a door and lowered the room temperature 3 or more degrees below the set temperature, the
fi
replace would light on
high
fl
ame when the remote sends the next signal.
When operating in MAN (manual) mode the
fi
replace will light on high
fl
ame every time.
As in the past, the fan will turn on/off automatically based on the temperature sensor below the
fi
replace.