Flue Adaptor with Liner
All fires need some type of adaptor to connect to the flue. The Jetmaster flue adaptor supplied may be attached
to the base of the flue liner first then pushed up while the outer firebox and inner fire box are slid into place.
After the fire is installed then, working from the inside it should be possible to pull the adaptor together with liner
downwards into the recess at the top of the fire. Once it has seated correctly then the 3 bolts must be screwed
into the nut fixings to hold it in place.
The Jetmaster fire is not a structural unit; although very robust it is not designed to take the weight of the flue.
Therefore a structural lintel will need to be provided for clay liners or in the case of pre fabricated stainless steel
chimney the chimney manufactures recommended fixing brackets or method must be used.
Flue Adaptor with Existing Flue
If the existing flue is to be used and the adaptor joined directly to the flue then the opening will need to be
prepared high enough to allow the outer box adaptor and any flue pipe to be slid in place and with sufficient room
to work to enable connection between fire and flue.
Flue Liner or Flue
(designated size)
Inner & Outer box
assembly
Flue adaptor
ADAPTOR REQUIRES
ENOUGH SPACE TO CLEAR
THE OUTER BOX AND
INNER BOX