Management and Monitoring
23
Figure 3-9
SAS Ports and Disk Drives Divided into Five Groups Configuration
Make sure to click the
Apply
button to apply the SAS zoning settings and click the
Restart
button to take effect.
Page 1: ...r JX Series Software Manual Applicable Models JetStor 824JXD JetStor 824JX JetStor 816JXD JetStor 816JX JetStor 812JXD JetStor 812JX JetStor 826JXD JetStor 826JX Advanced Computer Network Corp www acn...
Page 2: ...ate as of its publication date The information is subject to change without notice Trademarks JetStor the JetStor logo JX series X series and acnc com are trademarks or registered trademarks of Advanc...
Page 3: ...6 disk 2U Chassis 826JX Single Controller SFF 26 disk 2U Chassis Information contained in this manual has been reviewed for accuracy But it could include typographical errors or technical inaccuracies...
Page 4: ...the applicable data for their specific environment This information contains examples of data and reports used in daily business operations To illustrate them as completely as possible the examples i...
Page 5: ...beView 4 2 2 1 Device Finder 6 2 2 2 Device List 6 2 2 3 Event Log 8 2 2 4 Dashboard 10 2 2 5 Agent Mode 10 2 2 6 About CubeView 12 3 Management and Monitoring 14 3 1 System Information 14 3 1 1 Firmw...
Page 6: ...iv Copyright 2017 Advanced Computer Network Corp All Right Reserved 4 3 Documentation Feedback 34 Appendix 35 End User License Agreement EULA 35...
Page 7: ...n 15 Figure 3 3 SAS Zoning Configuration 17 Figure 3 4 All SAS Ports Access All Disk Drives Diagram 18 Figure 3 5 All SAS Ports Access All Drives Configuration 19 Figure 3 6 SAS Ports and Disk Drives...
Page 8: ...vi Copyright 2017 Advanced Computer Network Corp All Right Reserved Tables Table 1 1 Operation System Compatibility 2 Table 2 1 CubeView Panel Layout 5...
Page 9: ...to service change disassemble or upgrade the equipment s components by yourself Doing so may violate your warranty and expose you to electric shock Refer all servicing to authorized service personnel...
Page 10: ...ion INFORMATION INFORMATION provides useful knowledge definition or terminology for reference TIP TIP provides helpful suggestions for performing tasks more effectively CAUTION CAUTION indicates that...
Page 11: ...Indicates optional values Example a b indicates that you can choose a b or nothing braces Indicates required or expected values Example a b indicates that you must choose either a or b vertical bar In...
Page 12: ......
Page 13: ...closure zoning function firmware update and history record of system temperature voltage and fan speed And designate certain disk drives for a dedicated SAS port for security SAS zoning Users can also...
Page 14: ...le It receives the SES command from the CubeView client and communicates with the JetStor series systems via SES protocol and then replies to the CubeView client CAUTION The SAS HBAs or SAS RAID cards...
Page 15: ...anguages Support Here are the CubeView supported languages it is auto switched by the language setting of operation system English French German Italian Japanese Korean Russian Traditional Chinese Sim...
Page 16: ...ubeView exe CubeView main file includes CubeView client and CubeView agent Windows version LZMA dll It is Windows dynamic link libraries please put it at the same directory as the CubeView exe file Th...
Page 17: ...sible by CubeView Section 2 2 2 3 Event Log Display the latest events of the selected JetStor system Section 2 2 3 4 Dashboard Click to show the status summary of the selected JetStor system Section 2...
Page 18: ...Figure 2 3 Device Finder 2 2 2 Device List All JetStor systems that connect to the CubeView will be shown in the device list Users can click the device on the list for detail information or start to...
Page 19: ...nique Identifier LED Upgrade Firmware Restart the system Shutdown the system Figure 2 5 System Information Managing and monitoring is under the system information in the main working area SAS Zoning D...
Page 20: ...the options Or click the icon to expand the option area For more information about the operations please refer to the chapter 3 Management and Monitoring 2 2 3 Event Log Event log of the CubeView wil...
Page 21: ...Getting Started 9 Figure 2 7 Event Log of Firmware Upgrade Figure 2 8 Event Log of Error on Power Supply and Fan...
Page 22: ...includes the following items Storage ID Device Slots Power Supply Cooling Device Temperature Sensor Voltage Sensor Status Figure 2 9 Dashboard Information The status shows OK if the items are fine If...
Page 23: ...tton will confirm switching to the agent mode The CubeView program will shrink to the Window taskbar Figure 2 11 CubeView Agent Icon on Taskbar Click the CubeView Agent icon will pop up a window to ad...
Page 24: ...eView client to inquire the status Figure 2 13 Authorized Client Assignment INFORMATION For more information about the CubeView client mode and agent mode please refer to the chapter 1 1 Introduction...
Page 25: ...Getting Started 13 Figure 2 14 About CubeView...
Page 26: ...ging tabs Figure 3 1 System Information Options of System Information The options available in this tab System Name Change the system name highlight the old name and type in a new one and then click t...
Page 27: ...ot the controller 1 first and then controller 2 after 30 seconds Shutdown Storage Click the Shutdown button to shutdown the system 3 1 1 Firmware Upgrade The basic information in the CubeView shows cu...
Page 28: ...1 Easy disk drive management Users can designate certain disk drive to be accessed by single SAS port For example users can designate disk drive slot 1 2 3 4 and 5 for the SAS port 1 the server can o...
Page 29: ...iguration TIP Please note that after applying new SAS zoning configuration you must reboot the JetStor system to make new zoning configurations take effect After restart the JetStor system server that...
Page 30: ...18 Copyright 2017 Advanced Computer Network Corp All Right Reserved Figure 3 4 All SAS Ports Access All Disk Drives Diagram The SAS zoning configuration is on the following...
Page 31: ...Management and Monitoring 19 Figure 3 5 All SAS Ports Access All Drives Configuration...
Page 32: ...ng setting for each port according to requirement Here is an example of two zones of SAS ports and disk drives SAS port 1 and 2 can access to the disk drive slot 1 12 and SAS port 3 4 5 can access to...
Page 33: ...Management and Monitoring 21 Figure 3 7 SAS Ports and Disk Drives Divided into Two Groups Configuration...
Page 34: ...es SAS port 1 can access to the disk drive slot 1 5 SAS port 2 can access to the disk drive slot 6 10 SAS port 3 can access to the disk drive slot 11 15 SAS port 4 can access to the disk drive slot 16...
Page 35: ...t and Monitoring 23 Figure 3 9 SAS Ports and Disk Drives Divided into Five Groups Configuration Make sure to click the Apply button to apply the SAS zoning settings and click the Restart button to tak...
Page 36: ...for host connectivity Port 2 is disconnected Zone 2 Port 3 and Port 4 Port 3 is for host connectivity Port 4 is disconnected Figure 3 10 Two Servers to One JetStor Two Zones Two Servers to Three JetS...
Page 37: ...formation and indicator control for the disk drives installed in slots Disk Drive information Show each disk drive s vendor model name and serial number Besides if the disk drive is healthy the device...
Page 38: ...se refer to chapter 2 System Components Overview in the JetStor JX Series Hardware Manual 3 4 Power Supply The Power Supply tab provides to monitor the status of power supply unit and indicate error c...
Page 39: ...put AC is abnormal too high low voltage AC FAIL indicator will be on and show dark red color Figure 3 13 Power Supply Status Indicators 3 5 Cooling Device The Cooling Device tab provides to monitor th...
Page 40: ...ature sensors There are some thermal sensors in the system Thermal sensor indicators will show the following information Temperature Sensor Name It indicates the location of the thermal sensor Current...
Page 41: ...Management and Monitoring 29 Figure 3 15 Temperature Sensor Status Indicators INFORMATION Temperature statistic charts will be updated by every minute...
Page 42: ...ors in the system Voltage sensor indicators will show the following information Voltage Sensor It indicates the voltage sensor Current Voltage Number by volt Voltage Status If the voltage detected by...
Page 43: ...Management and Monitoring 31 Figure 3 16 Voltage Sensor Status Indicators 3 8 SAS Expander The SAS Expander tab provides the SAS expander information including the SAS addresses...
Page 44: ...Figure 3 17 SAS Expander Information 3 9 SAS Port The SAS Port tab provides to monitor the status of the SAS ports There are five SAS ports on each controller The connectivity status and speed for ea...
Page 45: ...or support ViaEmail support acnc com Information to collect Product name model or version and serial number Operating system name and version Firmware version Error messages or capture screenshots Pro...
Page 46: ...ittedto providingdocumentationthat meets and exceedsyour expectations To helpus improvethe documentation emailany errors suggestions or comments to support acnc com When submitting your feedback inclu...
Page 47: ...exclusive non transferable non distributable non assignable non sub licensable license to install and use the Product pursuant to the terms of this EULA Any right beyond this EULA will not be granted...
Page 48: ...LAR DAMAGES OR LIABILITIES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOSS OF DATA INFORMATION REVENUE PROFIT OR BUSINESS ARISING OUT OF OR RELATING TO THE USE OR INABILITY TO USE THE PRODUCT OR OTHERWIS...
Page 49: ...ULA will be binding upon and will inure to User s successors and permitted assigns This EULA shall be governed by and constructed according to the laws of R O C Any disputes arising from or in connect...