32 ©
Copyright 2017
Advanced Computer & Network Corp
. All Right Reserved.
CLI >
temp
Quantity of temperature sensors: 11
Temperature Sensor
Value Status HighCrit HighWarn LowWarn LowCrit
---------------------------------------------------------------------------
Ctrl 1 Backend Connector
30C
OK
75
65
5
0
Ctrl 1 Location Bottom Right 42C
OK
75
65
5
0
Ctrl 1 SAS Wide Port 1
29C
OK
75
65
5
0
Ctrl 1 SAS Expander
65C
OK
95
90
5
0
Ctrl 2 Backend Connector
30C
OK
75
65
5
0
Ctrl 2 Location Bottom Right 41C
OK
75
65
5
0
Ctrl 2 SAS Wide Port 1
29C
OK
75
65
5
0
Ctrl 2 SAS Expander
65C
OK
95
90
5
0
Backplane Location Left
30C
OK
70
65
5
0
Backplane Location Middle
34C
OK
70
65
5
0
Backplane Location Right
29C
OK
70
65
5
0
Table 2-2
Temperature Sensor Description
Column Name
Description
Status
The status of the temperature sensors:
OK: The thermal sensor is present and no error.
CRIT: The thermal sensor detected a critical error condition.
WARN: The thermal sensor detected a warning error condition.
FAIL: The thermal sensor is not accessible.
2.6.2.
Show Voltage Information (volt)
Command
volt
Description
Show the voltage sensors information of the system.
Syntax
volt
Parameters
none