58
Operation Manual
Installation
1. Install a new O-ring (Figure 94) onto the
gland nut.
2. Install the guide bushing (Figure 94) and
plunger into the gland nut.
3. Place the new packing and guide bush-
ing onto the plunger. Orient the packing
as shown in (Figure 91) for 15K/20K and
(Figure 92) for 40K.
4. Lubricate the gland nut with anti-seize
compound. Apply the compound to the
threads and on the small face that con-
tacts the inside of the stuffing box (
ure 95). Place the assembly into the stuff-
ing box. Hand-tighten the gland.
Figure 95: Applying Anti-Seize.
Figure 94: Guide Bushing Installation.
Guide
Bushing
O-Ring
Anti-Seize
Anti-Seize