42
Operation Manual
Figure 54: Secondary Filter Assembly.
Cover
A
Filter Bag
Pressure Gauge
Pressure Switch
Filter Inspection
1. Loosen the 3 eye bolts (Figure 52) secur-
ing the filter housing cover and swing the
lid open.
2.
filter housing and inspect for debris.
Replace as necessary.
Secondary Filter (40k Operation Only)
The secondary filter, or polishing filter, is used
for 40K operation only. When operating at 40K,
monitor the filter pressure gauge (
for an indication of filter condition. During
normal operation, the pressure gauge should
be within the 30 to 40 psi (2 to 2.75 bar) range.
When differential pressure inside the filter
housing between the clean side and the dirty
side drops approximately 7 to 10 psi (0.48 to
0.69 bar), the pressure switch on the filter
housing will trip and the engine will shut off to
protect the unit from damage. Replace the
dirty filter cartridge if this occurs.
ATTENTION
Filter bags are not washable. Any attempt to wash
or flush a bag for reuse could damage the bag.
This may allow debris past the filter and into the
valves causing damage.
ATTENTION
Extended operation with a dirty filter will lead to
filter failure and allow debris to reach the valves
causing damage to the valves.
It is important to know the condition of your
filter cartridge. Standard units come with a
pressure gauge on the filter. In order to monitor
the condition of the filter it is important to note
the engine operating speed and housing pressure
when the filter is first changed. Refer to
Cartridge Replacement” on page 43 for more
information.
Figure 53: Filter Bag Removal.
Figure 52: Filter Housing Cover
Summary of Contents for TwinForce Series
Page 1: ...OPERATION MANUAL TwinForce Series Waterblast Unit...
Page 2: ...Visual Safety System...
Page 11: ...3 TwinForce Series Waterblast Unit...
Page 22: ...14 Operation Manual...
Page 42: ...34 Operation Manual...
Page 48: ...40 Operation Manual...
Page 52: ...44 Operation Manual...
Page 100: ...92 Operation Manual...
Page 104: ...96 Operation Manual...
Page 106: ...A 2 Appendix A Technical Specifications...
Page 107: ...B 1 TwinForce Series Waterblast Unit APPENDIX B LONG TERM STORAGE PROCEDURE...