safety instructions

IMPORTANT: READ AND fOllOw All INSTRUCTIONS PRIOR TO INSTAllATION 

AND USE.  SAvE ThESE INSTRUCTIONS fOR fUTURE REfERENCE.

Operational:

Do not permit children to use unit unless they are closely supervised at all time. Supervision is also required when 

1. 

the bath is used by an elderly or handicapped individual. 

Use this unit only for its intended use as described in this manual. Only use attachments recommended by the manufacturer. 

2. 

Do not insert any object into any opening. Do not operate electrical appliances while in or within 5 feet of the bath. 

3. 

Do not operate this unit without the guard over the suction fitting. Long hair must be kept away from the suction 

4. 

screen to avoid entrapment. If entrapment occurs, immediately turn unit off. 

Do not start pump before unit is filled with water 2” above jets – this will void the warranty.

 

5. 

Water level should not exceed the lowest edge of the overflow or controls. 

 

6. 

The water in a whirlpool should not exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C 

7. 

(104°F) are typically considered safe for a healthy adult. Prolonged immersions in hot water may produce hyper

-

thermia. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, 

lethargy, drowsiness and fainting, which can be fatal. Lower temperatures are recommended for extended use 

(exceeding 10-15 minutes) for young children.

 

Exposure to very hot water has the potential to cause fetal damage during the early months of pregnancy. Preg-

8. 

nant, or possibly pregnant women should limit water temperature to 38°C (100°F). Consult a

 

physician before using. 

Persons using medication should consult a physician before using a whirlpool since medication may induce drowsi-

9. 

ness, affect heart rate, blood pressure and circulation. The use of alcohol, drugs or medication before or during 

whirlpool use may lead to unconsciousness with the possibility of drowning. 

Persons suffering from obesity or with a medical history of heart disease, low or high blood pressure, circulatory 

10. 

system problems, or diabetes should consult a physician before using a whirlpool.  

Electrical:

This unit must be connected to a supply circuit that is protected by a ground-fault-circuit-interrupter (GFCI). Such 

1. 

a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the 

test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to 

operate in this manner, there is a ground current flowing indicating the possibility of an electric shock. Do not use 

this unit. Disconnect the unit and have the problem corrected by a qualified service representative before using. 

 

Disconnect power before servicing.  

2. 

Whirlpool Pump Connections Only: 

3. 

 

a. A green colored terminal (or wire connector marked “G”, “GR”, “Ground” or “Grounding”) is provided within the 

terminal compartment. To reduce the risk of electric shock, connect this terminal or connector to the grounding ter-

minal of your electric service or supply panel with a continuous green insulated copper wire equivalent in size to the 

circuit conductors supplying this equipment. 

 

b. A pressure ground connector is provided on the exterior of the terminal box within this unit to permit connection 

of a No. 8 AWG (8.4mm²) solid copper bonding conductor between this unit and all other electrical equipment and 

exposed metal in the vicinity, as needed to comply with state and local requirements.  

For whirlpools and soakers the Mood or LED light option has its own separate power cord and must be plugged in.  

4. 

Install to permit access for servicing (for built-in and custom units).

 

5. 

Installer / Owner bears all responsibility to comply with all state and local codes when installing this product. 

6. 

Summary of Contents for Baths

Page 1: ...www jettacorp com Owner s Manual Installation Guide This manual is to be given to the product owner and should be kept for future use...

Page 2: ...OUR BEST CHOICE 4 SAFETY INSTRUCTIONS 5 INSTALLATION INSTRUCTIONS 6 INSTALLATION INSTRUCTIONS optional skirt 7 MAINTENANCE CLEANING 8 OPERATING INSTRUCTIONS CLASSIC SERIES 9 OPERATING INSTRUCTIONS DES...

Page 3: ...ature after 30 minutes of use This insulation also means that distractive motor noises and vibrations are virtually eliminated allowing you to escape from the world a little bit longer In this manual...

Page 4: ...irection adjustable at the jet to allow focused water flow Each full size jet is volume adjustable for a truly customized hydro massage Our air option can be added to most whirlpool baths to create th...

Page 5: ...i 9 ness affect heart rate blood pressure and circulation The use of alcohol drugs or medication before or during whirlpool use may lead to unconsciousness with the possibility of drowning Persons suf...

Page 6: ...rywall mud When leveling prepare a bed of moist mortar in the area where bath is to be installed Place equally spaced mounds of bedding compound about one foot apart 2 to 4 tall this should be about t...

Page 7: ...l of the tub Check the underside of the tub lip for smoothness there may be fiberglass chop that requires sanding so the skirt will fit snugly in place Slide the notched top edge of the skirt under th...

Page 8: ...then wipe with a dry cloth until the original gloss is restored Repairs of any kind if necessary should be done by qualified acrylic experts 3 Proper installation and maintenance will ensure years of...

Page 9: ...clockwise To adjust the jet direction use your finger to position the jet nozzle to the desired location To remove jet grasp the outer ring of the jet and turn counter clock wise until the jet clicks...

Page 10: ...to decrease rotation position the jet nozzle closer to the center of the jet Directional Body jets To increase the jet pressure grasp the outer ring of the jet and turn clockwise to reduce jet pressu...

Page 11: ...11 2013 Jetta Corporation All rights reserved REV 05 2013 www jettacorp com owner s manual operating instructions for optional air bath feature Mood Light Optional Heated Quiet Flo Blower...

Page 12: ...2013 Jetta Corporation All rights reserved REV 05 2013 800 288 7771 12 owner s manual operating instructions for optional air bath purge cycle...

Page 13: ...stuck Tap on rectangle box located on top of motor 2 to the right of where the power cord enters the box on the vertical surface of the rectangle box this should release the stuck points in the relay...

Page 14: ...industrial baths from date of manufacture 4 The equipment warranty is valid for five 5 years for residential baths and one 1 year for commercial hotel or industrial baths from date of manufacture 5 T...

Page 15: ...425 Centennial Blvd Edmond OK 73013 Corporate 405 340 6661 Toll Free 800 288 7771 Fax 405 348 9745 www jettacorp com REV 05 2013 tub label...

Reviews: