2
Mechanical installation
2.1
Mounting instructions
AvoiD At All CoStS thAt ...
moisture enters into the device
drill chips, screws or foreign objects fall into the device.
Please note:
This device is intended exclusively for installation inside a stationary
control cabinet. The control cabinet must at least meet the IP44 degree
of protection. When using the safety functions (STO and SBC) in the
servo amplifier, the control
cabinet must have a degree of protection of
IP54 or higher in accordance with EN ISO 13849-2.
Do not install servo amplifiers in areas where they will be exposed to
continued shocks. Further information can be found in the appendix.
Maximum pollution degree 2 according to EN 60664-1. For more
information on environmental conditions see the Appendix.
The best result for an EMC-compliant installation can be achieved with
a chromated or galvanized mounting plate. If the mounting plates have
been painted, remove the paint from the contact areas! The devices
themselves have a blue chromated zinc frame.
Note:
When installing the servo amplifier within a multi-axis system, the operating
instructions of the other devices (supply unit, controller etc.) must also be
observed.
Jetter AG
17
JetMove 3000
Mechanical installation