2.1.1
order and arrangement
The following basic guidelines apply to the arrangement and installation of
the supply unit and servo amplifiers:
line-up and order
The devices can be mounted directly next to each other and without
any gaps between them. They are fastened with two/four screws to
the mounting plate. Control and power voltages are fed to the servo
amplifiers (JM-3000) via DC link and 24 VDC busbars from the supply
unit. Thanks to the same cooling concept, this is possible without
additional compensation measures with regard to device depth.
The units must be mounted in the specified order in a row as shown in
Fig. 2.1. A different order is not permissible, as otherwise problems with
the busbar and the mutual thermal influence will occur.
1
2
3
1) JM-3000 supply unit
2)
JM-3000 servo amplifier
3) additional JM-3000 servo
amplifier
Fig. 2.1 Order of line-up
CAUtIoN
Hot surfaces
Protection against hot surfaces during operation. Temperatures of up to
100 °C can occur on the heat sink of the unit. Please ensure that there is
sufficient distance to adjacent modules, especially above the heat sink,
CAUtIoN
Protection against hot surfaces during operation. Provide suitable
protection against accidental contact with the heat sink.
Mechanical installation
18
Jetter AG