Abbreviation
Designation
Details
Via busbar
24 V supply voltage of control unit
DC link supply (DC link +/-)
X3
Input of cross communication
X4
Output of cross communication
X5.1
EtherCAT IN, fieldbus input
Can also be used as EtherNet interface for
PC
X5.2
EtherCAT OUT, fieldbus output
X6
Digital inputs (programmable)
X7
Encoder interface
see Table 3.2 and the following
X8
Encoder interface
X9
Encoder interface
X10
Encoder interface
X11
Digital inputs (safety function)
S-ADR
DIP switch for configuration of S1 functionality
see JM-3000 S1 User Manual
(Item # 60880300)
X12
Power connection, motor 1
With integrated connections for motor brake
and temperature monitoring
X13
Power connection, motor 2
X14
Power connection, motor 3
JM-35xx
JM-3000 single-axis servo amplifier
JM-D35xx
JM-3000 twin-axis servo amplifier
JM-T35xx
JM-3000 triple-axis servo amplifier
Table 3.1
Legend: Connections of JM-3000 servo amplifier
Jetter AG
37
JetMove 3000
Electrical installation