4.1.1
Flashing code
The amber LED has a defined function only during a software update:
leD, amber
leD, red
long
(0.8 s)
leD, green
Axis status
long
(0.8 s)
short
(0.4 s)
-
Reset/start or firmware update
-
-
-
-
Self-initialization at device start
-
¡
®
1 x
®
1 x
Not ready
-
¡
®
2 x
®
2 x
Switch on disabled
-
¡
®
3 x
®
3 x
Axis ready
-
¡
®
4 x
®
4 x
Axis switched on
-
¡
®
5 x
Operation enabled
-
¡
®
6 x
®
6 x
Quick stop
-
Error code
®
7 x
®
7 x
Response to error active
Error code
®
8 x
®
8 x
Error
1)
-
-
-
PtP-Ethernet connection in service and diagnos-
tics mode via the EtherCAT interface
= LED is ON
¡
= LED is OFF
®
= LED is flashing
LED, green, flashing long = motor in normal operation
LED, green, flashing short = motor in simulation mode
LED, amber: Axis 1/2/3
Status: ON
=
Reset/start
1) LED, amber: Axis 1/2/3
Status: Flicker-
ing
Status: Flash-
ing
Status: OFF
= Interface X5.1 switches over with the next power on
= Interface is in Ethernet mode, additionally the "RUN" LED at X5.1 flickers.
= Interface works in EtherCAT mode
Table 4.1 Status LEDs - Flashing code