A.4 Switching device - Current data JM-3xxx 6 ... 32 A
JM-3000 servo amplifier
U
Mains
F
S
Unit
JM-3506
JM-D3506
JM-t3506
Rated current
230 V
2 kHz
A
6
2 x 6
3 x 6
Maximum current for 10 s
A
12
2 x 12
3 x 12
Maximum current for 500 ms
A
18
2 x 18
3 x 18
Maximum current at F
M
= 0 Hz
A
14.7
2 x 14.7
3 x 14.7
Rated current
230 V
4 kHz
A
6
2 x 6
3 x 6
Maximum current for 10 s
A
12
2 x 12
3 x 12
Maximum current for 500 ms
A
18
2 x 18
3 x 18
Maximum current at F
M
= 0 Hz
A
12.3
2 x 12.3
3 x 12.3
Rated current
230 V
8 kHz
A
6
2 x 6
3 x 6
Maximum current for 10 s
A
12
2 x 12
3 x 12
Maximum current for 500 ms
A
12.5
2 x 12.5
3 x 12.5
Maximum current at F
M
= 0 Hz
A
8
2 x 8
3 x 8
Rated current
230 V
12
kHz
A
4
2 x 4
3 x 4
Maximum current for 10 s
A
8
2 x 8
3 x 8
Maximum current for 500 ms
A
9.7
2 x 9.7
3 x 9.7
Maximum current at F
M
= 0 Hz
A
6.2
2 x 6.2
3 x 6.2
Rated current
230 V
16
kHz
A
2.9
2 x 2.9
3 x 2.9
Maximum current for 10 s
A
5.8
2 x 5.8
3 x 5.8
Maximum current for 500 ms
A
7.6
2 x 7.6
3 x 7.6
Maximum current at F
M
= 0 Hz
A
4.8
2 x 4.8
3 x 4.8
Rated current
400 V
2 kHz
A
6
2 x 6
3 x 6
Maximum current for 10 s
A
12
2 x 12
3 x 12
Maximum current for 500 ms
A
18
2 x 18
3 x 18
Maximum current at F
M
= 0 Hz
A
14.7
2 x 14.7
3 x 14.7
Rated current
400 V
4 kHz
A
6
2 x 6
3 x 6
Maximum current for 10 s
A
12
2 x 12
3 x 12
Maximum current for 500 ms
A
18
2 x 18
3 x 18
Maximum current at F
M
= 0 Hz
A
12.3
2 x 12.3
3 x 12.3
Rated current
400 V
8 kHz
A
6
2 x 6
3 x 6
Maximum current for 10 s
A
12
2 x 12
3 x 12
Maximum current for 500 ms
A
12.5
2 x 12.5
3 x 12.5
Maximum current at F
M
= 0 Hz
A
8
2 x 8
3 x 8
Notes
: Current data per axis in the servo amplifier 230/400/480 V AC refers to the supply voltage of the supply unit.
Table A.7
Current data of the 6 amp servo amplifiers
Appendix
84
Jetter AG