Mechanical conditions
JM-3000
Vibration limit during
transport
To EN 61800-2, IEC 60721-3-2 class 2M1
Frequency [Hz]
Amplitude [mm]
Acceleration [m/s²]
2 ≤ f < 9
3.5
Not applicable
9 ≤ f < 200
Not applicable
10
200 ≤ f < 500
Not applicable
15
Shock limit value during
transport
To EN 61800-2, IEC 60721-2-2 class 2M1
Height of fall (units within packing): 0.25 m max.
System vibration limits
1)
To EN 61800-2, IEC 60721-3-3 class 3M1
Frequency [Hz]
Amplitude [mm]
Acceleration [m/s²]
2 ≤ f < 9
0.3
Not applicable
9 ≤ f < 200
Not applicable
1
1) Note: These devices are only intended for stationary use.
Table A.13 Mechanical conditions JM-3000
NotICe
DAMAGe to tHe DevICe DUe to INCoRReCt
AMBIeNt CoNDItIoNS
FAIlURe to oBSeRve tHe AMBIeNt CoNDItIoNS CAN ReSUlt
iN DAMAGE to ProPErty.
y
No continued shocks!
Do not install servo amplifiers in areas where they will be exposed to
continued shocks.
y
For STO, the control cabinet must be at least IP54 according to EN
ISO 13849-2.
y
Observe the cooling conditions.
Note:
These devices are only intended for stationary use.
Jetter AG
93
JetMove 3000
Appendix