Jetter AG
Programming | 8
User Manual – JetViewMobile 205
24
Object ID
Description
1041
Messaging: New settings become active after a restart.
Appears for example after the language of the system menu is
changed.
1042
Alarm mask: Shows the "Shutdown" messaging.
Appears while the system is being shut down.
1050
Alarm mask: Error during download (outdated).
1051
Alarm mask: Error: Connection lost.
1052
Alarm mask: Error during update via USB.
1053
Alarm mask: Error: USB stick not found.
1054
Alarm mask: Error: Information about parsing error.
1100
Stop key pressed.
Appears in the system menu only when the Stop key is
pressed.
Tab. 19: Data mask/alarm mask objects
FillAttributes objects
These objects can be used to define different background colors for incorrect val-
ues in input fields. The numeric editor checks for min/max values. As soon as a
value is outside of the permitted range, object 101 is used, otherwise object 100.
Object ID
Description
100
Used when the entry in the editor field is correct.
Set this attribute on rectangle object 200.
101
Used when the entry in the editor field is faulty.
Set this attribute on rectangle object 200.
Tab. 20: FillAttribute objects
Rectangular objects
Object ID
Description
200
Editor field
Tab. 21: Rectangular objects
String variables
Object ID
Description
65000
Content of the editor field.
65001
Original value of the edited object.
65002
Serial number
65003
Manufacturing date
65004
Software version
65005
Hardware revision
65006
Device type
65007
ActiveObjectPool version