20
Jetter AG
Place of installation, ambient conditions
DANGER
Danger in potentially explosive atmospheres!
The motor can become a source of ignition in potentially explosive
atmospheres.
When using a motor in an area with potentially explosive
atmosphere, it must have an ATEX approval corresponding to the
respective protection zone.
Jetter servo amplifiers do not have ATEX approval and must
therefore not be installed in hazardous areas.
The servo motors comply with the degree of protection IP65.
CAUTION
Observe the degree of protection at installing the motor!
If an incorrect degree of protection is assumed, personal injury and
damage to property may occur.
Install the motor with the degree of protection required for the
application.
Protect the motor from harmful environmental influences.
The motor must be easily accessible.
Operating temperature: -15 ... +40 °C
Operating altitude: Max. 1,000 m above sea level
Relative humidity: 15 ... 85 %, non-condensing
Important:
Operation at higher temperatures and altitudes will necessarily require a
derating.
The power reduction (derating) depending on the operating altitude and
operating temperature is:
From 1,000 to 4,000 m 0.6 % per 100 m increase in altitude
From 40 °C to 80 °C 6 % per 1,000 m increase in altitude.
For further technical data, please refer to the User Manual of the servo
motors.
Servomotoren | Jetter - We automate your success
https://www.jetter.de/en/downloads/motion-systems/servo-motors.html
Motor as ignition source
in potentially explosive
atmosphere
Caution when assuming
the wrong degree of
protection
Suitable places of
installation
Environmental
conditions - General
information
Summary of Contents for JHN Series
Page 1: ...Installation Manual JHN JHQ and JL Servo Motors 60881738 We automate your success...
Page 6: ......
Page 43: ......