Jetter AG
Technical specifications | 4
JVM-104-O09 User Manual
14 / 62
Category
Description
Maximum total current
The total current of all outputs must not exceed 8
A, otherwise shutdown after 500 ms.
If the total current exceeds 10.5 A, the outputs shut
off immediately.
Tab. 16:
Technical data – Digital output
PWM output
Category
Description
PWM frequency
100 Hz ... 1 kHz
Resolution of pulse control
factor (duty cycle)
0.1 %
Accuracy of pulse control
factor (duty cycle)
+/- 42 ns
Maximum rated current
Supply voltage VBAT_PA
Switching frequency
100 Hz ... 1kHz
Protective circuitry
Overvoltage, overcurrent
Diagnostics
Overcurrent, cable break
Maximum total current
The total current of all outputs must not exceed 8
A, otherwise shutdown after 500 ms.
If the total current exceeds 10.5 A, the outputs shut
off immediately.
Tab. 17:
Technical data – PWM output
H-bridge
Category
Description
Maximum rated current
Supply voltage VBAT
Maximum output current
2.5 A
Peak current
~ 5 A, max. 500 ms
Current measuring accu-
racy
+/- 20 %
Switching frequency (1/pe-
riod length)
100 Hz ... 1 kHz
Frequency accuracy
+/- 42 ns
Resolution of pulse control
factor (duty cycle)
0.1 %
Diagnostics
Overcurrent
Tab. 18:
Technical data – H-bridge
4.9 EMI values
The JVM-104-O09 has E1 approval according to ECE R10 Rev. 5 and CE con-
formity according to ISO 14982.
Pulses to ISO
7637-2
Test pulse
Values
Functional class
1
-450 V
C
2a
+37 V
A
2b
+20 V
C
3a
-150 V
A
3b
+150 V
A