118
Jetter AG
9 Automatic copying of controller data
Automatically loading data file information
The JVM-507B is able to retrieve a data file before the application program is
launched.
The data file must be named
register.da
and stored to the folder
app
.
The table below shows how the device retrieves data file information:
Step
Description
1
If the data file
register.da
has been stored to the folder
app
, the device
detects this file on its next launch.
2
The device retrieves the file.
3
The device maps the values to the registers.
4
Once the device has retrieved the file, it deletes the data file.
5
The device loads the application program.
Mechanical operation
Prerequisites
Procedure