148
Jetter AG
Appendix
Operating parameters - EMC
This device is approved to E1 type approval.
Type approval number: e1*72/245*2009/19*6722*01
This device has been tested as per Directive ECE-R10 Rev. 04 and meets all
test criteria.
Parameter
Value
Standard
Interference immunity to
conducted faults
Pulse 1: Function status C
Pulse 2a: Function status A
Pulse 2b: Function status C
Pulse 3a/b: Function status A
Pulse 4: Function status A
Pulse 5b: 1 Ohm/50 V
Function status C
Complies with ISO
7637-2
Interference immunity to
external magnetic field
30 V/m
E1 type approval
EMC - Emitted
interference
EMC - Immunity to
interference