background image

Jetter AG
Graeterstrasse 2

71642 Ludwigsburg

Germany

Phone

Switchboard

+49 7141 2550-0

Sales

+49 7141 2550-531

Technical Hotline

+49 7141 2550-444

E-mail

Technical Hotline

hotline@jetter.de

Sales

sales@jetter.de

Translation of the german original User
Manual

Revision

2.01

Date of issue

8/12/2020

This document has been compiled by Jetter AG with due diligence, and based on the known
state  of  the  art.  Revisions  and  further  development  of  our  products  are  not  automatically
mentioned in a reviewed document. Jetter AG shall not be liable for errors in form or content,
or for missing updates, as well as for damages or disadvantages resulting from such failure.

Summary of Contents for JX3-PS1

Page 1: ...User Manual JX3 PS1 We automate your success...

Page 2: ...german original User Manual Revision 2 01 Date of issue 8 12 2020 This document has been compiled by Jetter AG with due diligence and based on the known state of the art Revisions and further develop...

Page 3: ...eans of status indication 10 3 5 Nameplate 10 3 6 Scope of delivery 10 4 Technical specifications 11 4 1 Dimensions 11 4 2 Mechanical specifications 11 4 3 Electrical properties 12 4 4 Environmental c...

Page 4: ...iv JX3 PS1 User Manual 7 Maintenance and repairs 21 7 1 Maintenance repairs and disposal 21 7 2 Storage and shipment 21 8 Service 22 8 1 Customer service 22 9 Spare parts and accessories 23 9 1 Spare...

Page 5: ...on our website This document is not subject to any updating service Start Jetter We automate your success For further information refer to the following information products Version updates Informati...

Page 6: ...to JX3 I O modules Operate the device only in accordance with the intended conditions of use and within the limits set forth in the technical specifications Intended use of the product includes its o...

Page 7: ...n death or serious injury WARNING Medium risk Indicates a potential hazardous situation which if not avoided could result in death or serious injury CAUTION Low risk Indicates a hazardous situation wh...

Page 8: ...not sufficient to supply all connected expansion modules 3 1 Design 1 4 3 2 1 5 9 6 7 8 Fig 1 Design 1 DIN rail latch 2 Housing 3 Backplane module 4 Connector X119 Connector for JX3 I O modules 5 DIN...

Page 9: ...a controller together with various expansion modules 1 Controller 2 1 Expansion module 3 Power supply module 4 Further expansion modules INFO Number of connectable expansion modules You can calculate...

Page 10: ...LEDs provide diagnostic options for various states LEDs Status Color Description R OFF No logic circuit supply ON Green Logic voltage supply is OK 3 5 Nameplate 6 3 1 2 5 4 Fig 4 Sample nameplate 1 Co...

Page 11: ...s Material Plastic Maximum height of fall Units within packing 1 m DIN EN 61131 2 DIN EN 60068 2 31 Units within product pack aging 0 3 m Vibration resistance Frequency sweeps 1 octave minute sinusoid...

Page 12: ...power output Pmax 24 W Tab 3 Power supply of JX3 system bus Electrical safety Category Description Standards Class of protection III DIN EN 61131 2 Dielectric test voltage Functional ground is con nec...

Page 13: ...0 dB V m at 10 m dis tance Frequency band 230 1 000 MHz Limit value 37 dB V m at 10 m dis tance Class B Tab 6 Emitted interference Immunity to inter ference Parameter Values Standards Magnetic field w...

Page 14: ...rds Asymmetric RF amplitude modulated Frequency band 0 15 80 MHz DIN EN 61131 2 DIN EN 61000 6 2 DIN EN 61000 4 6 Test voltage 10 V AM 80 with 1 kHz Source impedance 150 Criterion A Bursts Test voltag...

Page 15: ...ll the device only in vertical position on the DIN rail DIN EN 60715 Keep the minimum distance to surrounding parts 1 2 Fig 6 Installing the device on the DIN rail 1 DIN rail 2 Upper latch 3 Minimum d...

Page 16: ...ase latch lets you remove the device from the DIN rail 2 A A 1 Fig 7 Removing the device from the DIN rail 1 DIN rail 2 DIN rail release latch A Detail view 1 Disconnect the system from the power supp...

Page 17: ...egree of protection IP20 is not guaranteed If you touch the EMC clip you may damage this clip A damaged clip may result in lower noise immunity Do not touch any electronic components once the enclosur...

Page 18: ...8 24 6 Electrical connection NOTICE Damages to material or functional impairment Improper implementation of the wiring harness may cause mechanical stress Protect the cables from bending twisting or c...

Page 19: ...he electric cabinet Application Note 016 Also refer to Application Note 016 EMC Compatible Installation of Electric Cabinets by Jetter AG The following instructions are excerpts from Application Note...

Page 20: ...of the iso lation 2 90 mm max AWG 16 28 Terminal range 0 13 1 5 mm Stripping length 10 mm Specification without wire end ferrules Single conductor H05 07 V U 0 2 1 5 mm Flexible conductor H05 07 V K...

Page 21: ...ice and its functions are not allowed In the case of modifications to the device any liability is excluded The original parts are specifically designed for the device Parts and equipment from other ma...

Page 22: ...e the contact form on our homepage Technical hotline Jetter We automate your success You are also welcome to send an e mail to our technical hotline hotline jetter de Please supply the following infor...

Page 23: ...device and cause damage to the product Only use accessories recommended by Jetter AG 9 1 Spare parts Component Item number Terminal labels 60870411 Male connector in spring cage technology 2 pin 60870...

Page 24: ...60873296 We automate your success Jetter AG Graeterstrasse 2 71642 Ludwigsburg www jetter de E mail info jetter de Phone 49 7141 2550 0...

Reviews: