background image

Jetter AG

Safety | 2

JX3-PS1 User Manual

6 / 24

2 Safety

2.1 General information

At the time of placing on the market, this product corresponds to the current state
of the art and meets the recognized safety rules. 
Besides this user manual, laws and regulations in the operator's country are rele-
vant to the operation of the product. The operator is responsible for complying
with the directives mentioned below:

Applicable legislation, rules, and regulations

Relevant accident prevention regulations

Accepted safety rules

EU directives and other country-specific regulations

2.2 Purpose

2.2.1 Intended use

This expansion module is used to supply power to JX3 I/O modules.

Operate the device only in accordance with the intended conditions of use, and
within the limits set forth in the technical specifications. 
Intended use of the product includes its operation in accordance with this man-
ual.

SELV

The operating voltage of this device is classified as Safety Extra Low Voltage and
is therefore not subject to the European Low Voltage Directive. The device may
only be operated from a SELV source.

2.2.2 Usage other than intended

This device must not be used in technical systems which to a high degree have
to be fail-safe.

Machinery Directive

This device is no safety-related part as per Machinery Directive 2006/42/EC, and
must, therefore, not be used for safety-relevant applications. This device is NOT
intended for the purpose of personal safety, and must, therefore, not be used to
protect persons.

Summary of Contents for JX3-PS1

Page 1: ...User Manual JX3 PS1 We automate your success...

Page 2: ...german original User Manual Revision 2 01 Date of issue 8 12 2020 This document has been compiled by Jetter AG with due diligence and based on the known state of the art Revisions and further develop...

Page 3: ...eans of status indication 10 3 5 Nameplate 10 3 6 Scope of delivery 10 4 Technical specifications 11 4 1 Dimensions 11 4 2 Mechanical specifications 11 4 3 Electrical properties 12 4 4 Environmental c...

Page 4: ...iv JX3 PS1 User Manual 7 Maintenance and repairs 21 7 1 Maintenance repairs and disposal 21 7 2 Storage and shipment 21 8 Service 22 8 1 Customer service 22 9 Spare parts and accessories 23 9 1 Spare...

Page 5: ...on our website This document is not subject to any updating service Start Jetter We automate your success For further information refer to the following information products Version updates Informati...

Page 6: ...to JX3 I O modules Operate the device only in accordance with the intended conditions of use and within the limits set forth in the technical specifications Intended use of the product includes its o...

Page 7: ...n death or serious injury WARNING Medium risk Indicates a potential hazardous situation which if not avoided could result in death or serious injury CAUTION Low risk Indicates a hazardous situation wh...

Page 8: ...not sufficient to supply all connected expansion modules 3 1 Design 1 4 3 2 1 5 9 6 7 8 Fig 1 Design 1 DIN rail latch 2 Housing 3 Backplane module 4 Connector X119 Connector for JX3 I O modules 5 DIN...

Page 9: ...a controller together with various expansion modules 1 Controller 2 1 Expansion module 3 Power supply module 4 Further expansion modules INFO Number of connectable expansion modules You can calculate...

Page 10: ...LEDs provide diagnostic options for various states LEDs Status Color Description R OFF No logic circuit supply ON Green Logic voltage supply is OK 3 5 Nameplate 6 3 1 2 5 4 Fig 4 Sample nameplate 1 Co...

Page 11: ...s Material Plastic Maximum height of fall Units within packing 1 m DIN EN 61131 2 DIN EN 60068 2 31 Units within product pack aging 0 3 m Vibration resistance Frequency sweeps 1 octave minute sinusoid...

Page 12: ...power output Pmax 24 W Tab 3 Power supply of JX3 system bus Electrical safety Category Description Standards Class of protection III DIN EN 61131 2 Dielectric test voltage Functional ground is con nec...

Page 13: ...0 dB V m at 10 m dis tance Frequency band 230 1 000 MHz Limit value 37 dB V m at 10 m dis tance Class B Tab 6 Emitted interference Immunity to inter ference Parameter Values Standards Magnetic field w...

Page 14: ...rds Asymmetric RF amplitude modulated Frequency band 0 15 80 MHz DIN EN 61131 2 DIN EN 61000 6 2 DIN EN 61000 4 6 Test voltage 10 V AM 80 with 1 kHz Source impedance 150 Criterion A Bursts Test voltag...

Page 15: ...ll the device only in vertical position on the DIN rail DIN EN 60715 Keep the minimum distance to surrounding parts 1 2 Fig 6 Installing the device on the DIN rail 1 DIN rail 2 Upper latch 3 Minimum d...

Page 16: ...ase latch lets you remove the device from the DIN rail 2 A A 1 Fig 7 Removing the device from the DIN rail 1 DIN rail 2 DIN rail release latch A Detail view 1 Disconnect the system from the power supp...

Page 17: ...egree of protection IP20 is not guaranteed If you touch the EMC clip you may damage this clip A damaged clip may result in lower noise immunity Do not touch any electronic components once the enclosur...

Page 18: ...8 24 6 Electrical connection NOTICE Damages to material or functional impairment Improper implementation of the wiring harness may cause mechanical stress Protect the cables from bending twisting or c...

Page 19: ...he electric cabinet Application Note 016 Also refer to Application Note 016 EMC Compatible Installation of Electric Cabinets by Jetter AG The following instructions are excerpts from Application Note...

Page 20: ...of the iso lation 2 90 mm max AWG 16 28 Terminal range 0 13 1 5 mm Stripping length 10 mm Specification without wire end ferrules Single conductor H05 07 V U 0 2 1 5 mm Flexible conductor H05 07 V K...

Page 21: ...ice and its functions are not allowed In the case of modifications to the device any liability is excluded The original parts are specifically designed for the device Parts and equipment from other ma...

Page 22: ...e the contact form on our homepage Technical hotline Jetter We automate your success You are also welcome to send an e mail to our technical hotline hotline jetter de Please supply the following infor...

Page 23: ...device and cause damage to the product Only use accessories recommended by Jetter AG 9 1 Spare parts Component Item number Terminal labels 60870411 Male connector in spring cage technology 2 pin 60870...

Page 24: ...60873296 We automate your success Jetter AG Graeterstrasse 2 71642 Ludwigsburg www jetter de E mail info jetter de Phone 49 7141 2550 0...