13
9. Troubleshooting guide
Cable becomes jammed in the pipe
1. Inform the people at the other end of the duct that a
problem has been experienced and the operator is
going to shut down the system.
2. Shut off the pneumatic air supply with the air control
valve, allowing the air pressure to be depressurized
from the duct and the air block.
3. Using the counter or the measurement on the cable,
determine where the blockage might be located.
4. Notify supervisor about problem and determine a
solution
accordingly.
Belt feed does not pull the cable
1. Assist the reel by pushing it and/or by pulling the
cable of the reel.
The cable run is hard to restart
1. Put air to the system with the belt drive. The belt can
after having stopped
be restarted after the air pressure has increased and
stabilized.
Belt feed does not start
1. Estop may still be engaged. Reset the estop button
by turning it clockwise.
Check oil canister.