9
F. Install cable in belt drive and tighten
• Insert duct, assembly, tighten knob into air block.
• Feed the cable between belt drive and through the rear cable guide.
• Tighten belt drive using the down screw knob to ensure even pressure on the cable.
• Tighten down so that the belts no longer slip at the push force setting determined in the crash test
procedure. Do not over tighten.
G. Power on the counter unit
H. Connect air compressor
NOTE: Ensure the air control valve is off before connecting the air hose.
• Attach the air compressor hose to the air compressor.
• Then connect the compressor hose to the blower unit. The unit uses a standard claw connect air
compressor coupling.
NOTE: Always use clean and dry air.
NOTE: Route all hoses properly to prevent tripping hazard.
To avoid creating a trip hazard always route
air hose out of the way and secured to a stable object.
The cable reel should be placed axially perpendicular to the length of the duct and typically 6ft (2m) or
more from the MJet V2. The MJet V2 must be positioned in-line between the cable to be installed and
the duct. The cable should not enter the MJet V2 at an angle of more than 10 degrees from the intended
axis of travel.