11
7. Blower operations
1. Verify adjustable push force
Verify adjustable push force is set to the established crash test value and the speed is at minimum.
2. Engage wheel drive
The wheel drive can be operated forward and backward. For installation,
engage the wheel drive in forward by pressing the button. Install the fiber into
the duct using push only until the installation has slowed.
3. Engage air
Slowly open the air control valve to allow air flow to the air block. Do not apply
maximum air pressure and flow at initial air engagement. Do not open the air
supply before adequate fiber has been pushed in (approx. >100M).
IMPORTANT
Do not exceed 16 bars when operating the unit.
Forced air creates flying debris.
Always wear personal protective equipment.
Motor is not covered by warranty if motor is overheated. When
exceeding maximum pushing force (clutch fully engaged), let the
motor cool down between the cycles.
4. Adjust speed
Use the button to adjust the drive speed to ensure smooth installation and match the amount of air
pressure being used so that the forces are working together, not against one another.
5. Install fiber cable
It may be helpful to guide/apply back tension to the fibre using your hand at the fibre entrance of the
machine to maintain control over the fibre.
6. Switch of the machine to prevent battery damage
When the battery is emptied, the engine stops. Still the display lights up. It is important not to forget to
switch off the machine or you will ruin the battery.