1. General information

The TriggAIR is a unique handheld device for installing fiber optic directly into a pipe. The TriggAIR consist 
of an air block with max air pressure of 16 bar and duct clamps for 5,0- and 7,0-mm ducts. The unit’s 12 
v battery operated drive wheel will combined with air install fibers from 0,5-3,0 mm into an airtight duct, 
at speeds of 0 to 0-150 m/min. With the build in digital LCD display, displaying speed and distances and 
the manometer you always have full control of the process. The start button can be locked in the speed 
you like for “automatic drive”. Reverse function helps if you need to pull out a fibre.

The TriggAIR is operated without tools. The built-in adjustable clamp force greatly optimizes the pulling 
stress on the fiber. The unit have an adjustable clutch for fibre security. This fiber protection system  
prevent damages on the fiber if the fiber hits an obstruction.

The TriggAIR is supplied in hard side case including the TriggAIR, box for seals, 2 pcs battery and charger.
As option for the TriggAIR you can get a tripod and reel arm kit for pre terminated fibre.

These operating instructions contain a full description of the TriggAIR, which have been designed for the 
purpose of feeding fiber through a duct. The duct must have previously been installed underground or 
overhead to receive the fiber cable and must be of enough length on exit to be received by the machine. 
The duct must be of material with enough compression strength for it to be adequately sealed in the 
duct clamps of the machine. The duct must be airtight up to a pressure of 16bar. Duct sizes range from  
5 mm-7 mm, while fiber optic fiber(s) range from 0,5 mm-3 mm.

The TriggAIR consists of an air block/duct clamp that is made in two halves that clamp together around 
the duct. The duct clamp holds a seal that the fiber optic fibre is feed through before entering the 
duct. The duct clamp can be used for both 5,0- and 7,0-mm ducts. Fiber seals can be interchanged to 
accommodate different fibre sizes. The duct is mechanically clamped between the duct clamps at the 
exit of the duct clamp, preventing movement in any direction. Seal is placed around the fibre when 
clamped.

The fibre cable is fed through the duct by a combined pulling/pushing force. The pulling force is achieved 
when pressurized air is fed into the air block and forced into the duct, generating drag on the fibre from 
the airflow passing over it. The pushing force is created by engaging the drive wheel system. As the drive 
wheel feeds the fibre cable into the duct, drag force is created by the airflow. The fibre cable flies in the 
duct, minimizing any resistance to being pushed in by the drive wheel.

The use of the TriggAIR for operations other than those described in this manual are considered  
dangerous and are discouraged. Use of this machine for work other then what is intended, relieves the 
manufacturer from any responsibility, civil or penal. The manufacturer's responsibility ceases, and the 
warranty is voided when one of the following occurs:
A. 

When TriggAIR is used for purposes other than what is detailed in this manual.

B. 

Tampering and/or modifications carried out without written approval of the manufacturer.

C. 

Not using original manufactured replacement parts.

D. 

Poor maintenance.

E. 

Not using supplied safety devices or equipment.

F. 

Connection of this unit to machines and/or parts not produced or authorized in writing by the  

 manufacturer.
G. 

The TriggAIR should not be used to install any fiber other than fiber optic fiber specified within  

 

the range outlined in this instruction manual.

Jetting AB is not responsible for injuries incurred as a result of improper use of the TriggAIR.

5

Summary of Contents for TriggAIR

Page 1: ...TriggAIR Product model type TriggAIR TriggAIR USER S GUIDE AND SAFETY MANUAL ...

Page 2: ...orm or by any means including photocopying recording or other electronic or mechanical methods without the prior written permission of the publisher For permission requests write to the publisher addressed Attention Permissions Coordinator at the address below Jetting AB Murgatan 1 522 35 Tidaholm Sweden jetting se info jetting se ...

Page 3: ...y information on this page and note specific safety requirements as explained by procedures in this manual Failure to follow these instructions could result in serious personal injury or death 3 Caution Noise will exceed 70 db Manufacturer Jetting AB Murgatan 1 522 35 Tidaholm Sweden jetting se info jetting se 46 502 65 90 10 ...

Page 4: ...echnical information 2 6 Safe operating practices 3 7 Unpacking the box 4 8 Set up the TriggAIR 5 8 Crash test 6 10 Blower operations 7 11 Maintenance 8 12 Troubleshooting guide 9 13 EC Declaration of Conformity 10 14 Notes 11 15 Section Page 4 ...

Page 5: ... in two halves that clamp together around the duct The duct clamp holds a seal that the fiber optic fibre is feed through before entering the duct The duct clamp can be used for both 5 0 and 7 0 mm ducts Fiber seals can be interchanged to accommodate different fibre sizes The duct is mechanically clamped between the duct clamps at the exit of the duct clamp preventing movement in any direction Sea...

Page 6: ...ed Adjustable 0 150 m min 3 Fiber sizes 0 5 mm to 3 0 mm 4 Duct sizes 5 0 and 7 0 mm D Electrical requirements 1 Power requirements Volt max 12 V 4 0 Ah 2 Power connection Milwaukee standard E Physical specifications 1 Height 260 mm 2 Length 200 mm 3 Width 120 mm 4 Weight 2 3 kg F Wheel drive specifications 1 Adjustable clamp force G Pipecoupling requirements 1 Must withstand maximum air pressure ...

Page 7: ...e and conduit 7 Use the blower only for its intended purpose 8 Do not place fiber reel too close to unit Place the reel far enough away from the unit to ensure proper control 9 Keep hands away from belt drive while blower is in operation B Electrical devices The motor controller and digital display are electrical devices Electrical shock hazards exist that could result in severe personal injury or...

Page 8: ...Batteries Battery Charger Robust protecting case Cable Seal Box User manual B Accessories Arm for preconnected fibre Tripod incl CEJN adaptor Table Bracket for mounting on Table 8 5 Set up the TriggAIR This manual contains setup and operating instructions for the TriggAir Do not connect power supply until setup is complete Behöver en bättre bild Behöver en bättre bild ...

Page 9: ... clamp force wheel using the screw knob to ensure even pressure on the fibre cable Do not over tighten F Adjust clutch for fibre security Adjust if needed tighten it by turning the knob right and loosing it by turning left G Connect battery to blowing unit H Connect air compressor NOTE Ensure the air control valve is off before connecting the air hose Attach the air compressor hose to the air comp...

Page 10: ... of fibers 0 5 mm diameter 1 Insert the fiber and seal inside the duct as it would be for the actual installation 2 Install a 1 to 2m test length of duct into the TriggAIR clamp 3 Block the end of the test length of duct 4 Tighten the wheel pressure on to the fibre with the wheel drive engaged in the forward direction until the fibre starts to install 5 Ram the fiber into the blocked end of the du...

Page 11: ... 16 bars when operating the unit Forced air creates flying debris Always wear personal protective equipment Motor is not covered by warranty if motor is overheated When exceeding maximum pushing force clutch fully engaged let the motor cool down between the cycles 4 Adjust speed Use the button to adjust the drive speed to ensure smooth installation and match the amount of air pressure being used s...

Page 12: ...s no longer able to effectively grip the fiber optic fiber X Duct pack seal replacement X Seals replacement Inspect seal before each use Wheel cleaning and tightening Inspect wheel and tighten before and after each use Clean after each use or when necessary Disconnect power supply and exhaust any air pressure before servicing any component on the TriggAIR Avoid handling leaking couplings valve sea...

Page 13: ...e duct clamp air block 3 Using the counter or the measurement on the fiber cable determine where the blockage might be located 4 Notify supervisor about problem and determine a solution accordingly Wheels does not pull the fiber 1 Assist the reel by pushing the cable of the reel 2 Adjust the clamping force Hard to restart after stop 1 Put more less air to the system 2 The wheel can be restarted af...

Page 14: ...14 10 EC Declaration of Conformity ...

Page 15: ...15 11 Notes ...

Page 16: ...TriggAIR USER S GUIDE AND SAFETY MANUAL Version 2021 12 ...