Hose Reel Brake Adjustment

The reels are equipped with an adjustable brake to 
prevent the hose from playing off the reel under its own 
weight. Tightening wingnut increases the drag on the reel, 
loosening decreases the drag. Adjust as desired. The brake 
only works in one direction (to resist hose moving off reel) 
(Figure 15).

Transportation and Storage

1.  Turn off the fuel valve and the battery isolation switch.
2.  Drain water from Jetter as needed.
3.  Coil hoses and secure equipment appropriately. All 

loose material must be removed. Transport remote reel 
separate from jetter.

4.  Jetter is equipped with wheels to allow transport over 

smooth level surfaces.

5.  Jetter weighs 195kg (approx.) Use appropriate 

equipment and methods to load and transport. Use 
all four points supplied at the top corners of the 
frame (Figure 6) when lifting. Use rigging with current 
certifications per the manufacturer’s instructions.

Maintenance Instructions

WARNING

Before performing any maintenance, engine switch 
battery isolation switch should be in OFF position and 
spark plug wires should be disconnected to prevent 
inadvertent operation. Open water control valve to 
release any fluid pressure in system.
Always wear safety glasses and gloves when 
performing any maintenance to help protect against 
drain chemicals and bacteria.

Cleaning

The hose should be cleaned as needed with hot, soapy 
water and/or disinfectants. Do not allow water to enter the 
engine or electrical system. Do not clean with pressure 
washer. Wipe the unit down with a damp cloth. 

Figure.15 - Brake Adjustment

Engine

Maintain the engine as directed in the engine operator’s 
manual supplied with the unit. An hour meter is included on 
the engine to monitor jetter use.

Battery

To change battery
1.  Unclip strap holding battery box top on, remove top.
2.  Disconnect ground (-) cable connection first, followed 

by positive (+) cable connection.

3.  Remove battery.
4.  Reverse procedure to install.
Replacement batteries should have the following  
specifications:
•  BCI Group/Type: U1
•  Size (L x W x H): 196 x 128 x 159 (mm)
•  Voltage: 12
•  Cold Cranking Amps (CCA): 350
•  Reserve Capacity (RC): 45
•  Terminal Type: Offset Lug Terminal (OLT)
•  Assembly Type: C
•  Max Charging Volt: 14.8

Pump Lubrication/Maintenance

Check the pump oil level prior to each use. Place the jetter 
on a level surface. Wipe any dirt and debris from the area 
of the dipstick and sight-glass. Oil level should be at the 
middle of the sight-glass (Figure 16). If needed, remove the 
dipstick and add SAE 15W-40 Mineral non-detergent oil, 
fill to half-way on the sight-glass. Do not overfill, reinstall 
dipstick.

Figure.16 - Checking Pump and Gearbox Oil Level

Summary of Contents for Scorpion G2

Page 1: ...duct serial number which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol Driven WARNING Read this Operator s Manual carefully before using this machine Failure...

Page 2: ...ne and Work Area Set Up Water Supply Drain Preparation Hose Set Up Jetter Hose Selection Chart Jetter Nozzle Selection Chart Operating Instructions Jetting the Drain Draining Water from System Using W...

Page 3: ...fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Cluttered benches and dark areas invite accidents Do not operate power tools in explosive atmosphe...

Page 4: ...ator must be able to shut off the water flow to reduce the risk of the jetter hose whipping causing striking and high pressure injection injuries Always use appropriate personal protective equipment w...

Page 5: ...Jetting Machine is a portable high pressure water jetter designed to use a combination of water pressure and flow to clear grease sludge sediment and roots out of drains A highly flexible and lightwe...

Page 6: ...arbox Check oil level ensure half way on sight glasses per Maintenance section Pre Operation Inspection WARNING Before each use inspect your water jetter and correct any problems to reduce the risk of...

Page 7: ...et up the jetter and work area according to these procedures to reduce the risk of injury from high pressure water chemical burns infections carbon monoxide and other causes and prevent jetter damage...

Page 8: ...m water use appropriate personal protective equipment to reduce the risk of burns When using in cold weather use precautions to prevent water from freezing in the pump This can damage the pump Drain P...

Page 9: ...cifically sized for the jetter being used Using incorrect nozzles can cause poor performance low operating pressure or low flow or may damage the jetter with excessively high pressures Make sure the n...

Page 10: ...er pipes 3 to 4 with tighter radiuses bends This nozzle is smaller in size and eliminates the quick connect to allow easier negotiation around bends in the line It has three rear jets with one facing...

Page 11: ...s and gloves and may also include equipment such as latex or rubber gloves face shields goggles protective clothing respirators and steel toed footwear Follow operating instructions to reduce the risk...

Page 12: ...n control the ON OFF action of a water control valve ball valve or foot valve Do not turn the valve ON yet In case of emergency you must be able to turn off water flow Be sure that you have good balan...

Page 13: ...a pressure washer is similar to use as a jetter and those instructions should be used in conjunction with the following 1 Locate an appropriate work area 2 Make sure all equipment has been properly i...

Page 14: ...ways wear safety glasses and gloves when performing any maintenance to help protect against drain chemicals and bacteria Cleaning The hose should be cleaned as needed with hot soapy water and or disin...

Page 15: ...epared If water freezes in the pump it can damage it After the tank is drained remove the hose from the water inlet filter Open all valves in the system and use compressed air to force any water out o...

Page 16: ...through each orifice to remove debris Remove nozzle and insert jet hose in drain line Run jetter to flush trapped air or debris Jetter won t start Not enough water in the tank Filter is clogged See J...

Page 17: ...17 SCORPION G2 MANUAL WATER JETTER DRAIN CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log...

Page 18: ...SCORPION G2 MANUAL WATER JETTER DRAIN CLEANER 18 NOTES...

Page 19: ...19 SCORPION G2 MANUAL WATER JETTER DRAIN CLEANER NOTES...

Page 20: ...jetwavegroup jetwave group jetwavegroup 72 74 Richmond Road Keswick 5035 Adelaide South Australia AU 61 8 8371 3599 sales jetwave com au jetwave com au jetwavegroup jetwave group...

Reviews: