5.4 Accessories 

 
You  can  only  use  the  accessories  described  in  this  instruction  manual  with  your  DELio

® 

microscope. 

However, you can use accessories from other manufacturers. In this case, please refer to the instructions 
described in the supplier’s instruction manual. 
 

Additional Accessories  

Reference 

Wide field eyepiece (WF) 10x 

– Field of vision 18 mm 

574 208 

Wide field eyepiece (WF) 16x - Field of vision 11 mm 

574 209 

Wide field eyepiece micrometric 10x - Field of vision 18 mm 

574 140 

Achromatic objective 60x retractable - O.N.: 0.85 

574 033 

Achromatic objective 100x retractable - O.N.: 1.25 

– Immersion oil 

574 034 

Semi-plane lens 60x retractable - O.N.: 0.85 

574 040 

Semi-plane lens 100x retractable - O.N.: 1.25 - Immersion oil 

574 042 

Plane lens 60x retractable - O.N.: 0.85 

574 219 

Plane lens 100x retractable - O.N.: 1.25 - Immersion oil 

574 220 

 

 

 
 
 

5.5 Microscope Dimensions and Weight  

Monocular and binocular models: 

Browse mode: l 180 x H 370 x P 375 mm 
Storage mode: l 180 x H 370 x P 278 mm 

Duo, trinocular and with integrated camera models: 

Browse mode: l 180 x H 378 x P 375 mm 
Storage mode: l 180 x H 378 x P 278 mm 

Weight: about 6 kg. 
 
 

6. 

Maintenance 

Protection from dust: after use, cover the device (cover supplied with the microscope). If dust is deposited 
on the lenses, blow using a syringe or a dust collector or use a marter hair brush: lenses are fragile and 
can be scratched by dust. 

We recommend : 
the dust collector ref. 574 198, 
the special optical cleaner ref. 102 146 
or the cleaning kit for microscopes ref. 574 066. 
 
 
Fingerprints: do not touch the lenses. If, however, they bear prints, remove them using a soft cloth or  an 
optical cleaning paper. 
 
We recommend : 
the optical cleaning paper ref. 803 092 
or the cleaning kit for microscopes ref. 574 066. 
 
 
Humidity: humidity, especially if combined with temperature, is particularly harmful for the optical elements 
mounted. Microscopes should be stored in a dry place, in a particularly exposed climate, in their polystyrene 
box with a dehumidifier bag. 

 

 28 

Summary of Contents for DELio 601 871

Page 1: ...Microscopie Microscopes polarisants DELio Observation Microscopie Observation Microscopy Fran ais p 1 English p 16 Version 0206 Microscopes polarisants DELio Polarizing microscopes DELio...

Page 2: ...od les binoculaire ou trinoculaire 6 4 3 Les objectifs 6 4 4 Le r glage de la but e de protection des lames 6 4 5 La platine 6 4 6 La mise au point 7 4 7 Le r glage de la duret de la vis macrom trique...

Page 3: ...hragme iris selon mod le D clairage Super LED 1 W ou halog ne selon les mod les E LED t moin de charge fonction charge non disponible sur les mod les avec clairage halog ne F T te monoculaire orientab...

Page 4: ...iff rentes configurations prenant en compte le choix parmi les diff rentes t tes les diff rents oculaires et objectifs Descriptifs complets pages 9 11 T te binoculaire orientable sur 360 inclin e 30 T...

Page 5: ...e mise sous tension non disponible sur les mod les quip s d clairage halog ne C Range c ble d alimentation Vous venez de faire l acquisition d un microscope de la gamme DELio et nous vous en remercion...

Page 6: ...r vue cf tableaux des caract ristiques techniques pages 9 11 Veiller ne pas jeter le mat riel d emballage Ainsi vous pourrez l utiliser pour stocker et transporter l instrument en toute s curit en cas...

Page 7: ...ns cette position la LED bleue t moin de mise sous tension l arri re du microscope est alors teinte et l clairage galement 2 possibilit s i la LED t moin de charge est verte le microscope est suffisam...

Page 8: ...glage dioptrique afin d obtenir une image nette Si vous portez des lunettes et qu elles ne vous g nent pas lors de vos observations gardez les cela limitera les r glages au minimum 4 3 Les objectifs...

Page 9: ...e v rifier que le changement de grossissement est r alis et que votre objectif est sur le trajet optique 4 7 Le r glage de la duret de la vis macrom trique Remonter la platine au maximum l aide de la...

Page 10: ...r le polariseur jusqu obtenir la position d extinction c est dire la position du polariseur ou la lumi re filtre le moins vous devez obtenir une teinte gris fonc Fixer le polariseur l aide de sa vis s...

Page 11: ...ur Objectifs Achromatiques 4x O N 0 10 10x O N 0 25 40x r tractable O N 0 65 Semi plans 4x O N 0 10 10x O N 0 25 40x r tractable O N 0 65 Tourelle 4 places orient e l arri re Protection But e de prote...

Page 12: ...vec pointeur Grand champ WF 10x Champ de vision 18 mm Objectifs Achromatiques 4x O N 0 10 10x O N 0 25 40x r tractable O N 0 65 Semi plans 4x O N 0 10 10x O N 0 25 40x r tractable O N 0 65 Tourelle 4...

Page 13: ...champ WF 10x Champ de vision 18 mm Objectifs Achromatiques 4x O N 0 10 10x O N 0 25 40x r tractable O N 0 65 Semi plans 4x O N 0 10 10x O N 0 25 40x r tractable O N 0 65 Tourelle 4 places orient e l a...

Page 14: ...laire et cam ra int gr e En mode utilisation l 180 x H 378 x P 375 mm En mode rangement l 180 x H 378 x P 278 mm Poids 6 kg environ 6 Entretien Protection contre la poussi re apr s usage recouvrir l a...

Page 15: ...t situ s derri re le microscope pr s de la connexion du cordon d alimentation N utiliser que des fusibles de type Temporis lent 500 mA 250 V 7 Service apr s vente La garantie est de 5 ans Le mat riel...

Page 16: ...4 2 Diopter Adjustment Binocular or Trinocular Models 20 4 3 Lenses 20 4 4 Blades Protective Buffer Adjustment 20 4 5 The Platinum 21 4 6 Fine Tuning 21 4 7 Adjusting the Coarse Screw Hardness 22 4 8...

Page 17: ...motion with iris diaphragm according to the model D Super LED 1 W lighting or halogen lighting depending on the models E LED charge indicator charge function not available on models with halogen light...

Page 18: ...n different configurations taking into account the choice between The different heads the different eyepieces and lenses Full descriptions pages 25 to 27 Binocular head rotated 360 inclined at 30 Mono...

Page 19: ...s with halogen lighting C Power cable tidy You have just acquired a DELio microscope and we thank you for that This high quality instrument is designed to perfectly meet the requirements of your teach...

Page 20: ...instrument should the need arise Remove the plastic cap of the head base and place it in its housing at the top of the stand Fasten the head using the 3mm Allen key supplied as far as it will go with...

Page 21: ...sufficiently charged ii the LED charge indicator is red the microscope needs to be charged In this case let the microscope charge until the LED becomes green The maximum charge time if the battery is...

Page 22: ...a sharp image If you wear your goggles and they don t bother you during your observations keep them this will limit adjustments to a minimum 4 3 Lenses 3 types of lenses can equip your DELio microsco...

Page 23: ...rry out macroscopic tuning quick adjustment using the coaxial control placed on each side of the microscope and then conduct the microscopic tuning fine adjustment so as to obtain a sharp image A comp...

Page 24: ...ightness is modified using the brightness adjustment button Two simple rules closing the diaphragm increases the contrast and the depth of focus but reduces the resolution the diaphragm opening should...

Page 25: ...scopes 4 To make an observation in LPNA polarized light not analyzed turn the analyzer to 0 To make an observation in LPA polarized light analyzed turn the analyzer 90 If you want to observe your slid...

Page 26: ...Microscopy Polarizing microscopes DELio ENGLISH 28 23 24...

Page 27: ...pointer Lenses Achromatic 4x O N 0 10 10x O N 0 25 40x retractable O N 0 65 Semi planes 4x O N 0 10 10x O N 0 25 40x retractable O N 0 65 Turret 4 positions directed towards the rear Protection Integ...

Page 28: ...of view 18 mm Wide field WF 10x Field of view 18 mm with pointer Lenses Achromatic 4x O N 0 10 10x O N 0 25 40x retractable O N 0 65 Semi planes 4x O N 0 10 10x O N 0 25 40x retractable O N 0 65 Turr...

Page 29: ...d WF 10x Field of view 18 mm with pointer Lenses Achromatic 4x O N 0 10 10x O N 0 25 40x retractable O N 0 65 Semi planes 4x O N 0 10 10x O N 0 25 40x retractable O N 0 65 Turret 4 positions directed...

Page 30: ...ht Monocular and binocular models Browse mode l 180 x H 370 x P 375 mm Storage mode l 180 x H 370 x P 278 mm Duo trinocular and with integrated camera models Browse mode l 180 x H 378 x P 375 mm Stora...

Page 31: ...nt Unplug the microscope before any fuse replacement Fuses are placed at the rear of the microscope next to the power cord connection Only use fuses of type Time delay 500 mA 250 V 7 After Sales Servi...

Page 32: ...Microscopy Polarizing microscopes DELio ENGLISH 32...

Reviews: