小牛电动
Niu Electric
- 55 -
Charger
Inspection
The original battery for this model must be charged with the dedicated charger that accompanies with
the scooter (the scooter charging with a non-original charger will cause irrecoverable damages to the
battery). Charging with a non-original charger may lead to the circuit or battery failure.
The scooter charging is prohibited strictly from being made immediately after scooter stop. The charging
should be made when the battery surface has been naturally cooled down (it is recommended to make
charging after 30 minutes).
Stop charging immediately if the battery has not been fully charged for more than 24 hours and the red
lamp does not turn to green, and then contact the after-sale service for inspection of the charger and
battery.
1. Connect the charger plug to a 110-240V home socket.
The charger indicator illuminates as green since the battery has not been connected.
Connect the battery for charging. The battery indicator illuminates as red
in charging. It will turn to be green
when the battery is fully charged. The charging should be stopped by
disconnecting first the 110-240V AC power supply and
then the scooter charger socket.
Test of the charger output voltage
Connect positive and negative terminals on the charger plug
to a digital multimeter that is commercially available for
measurement of the charger output voltage.