Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 –
PURE (EN) June 2018
7
CAUTION
-
For good performance do not remove completely the ashes of the stove.
-
When the fire needs a reloading, set the speed controller on minimum. Open slightly
the door in order to avoid reverse flow of smokes in the room. After loading, do not
forget to position ventilation on the desired position.
-
If you have a device with ventilation, never make it work without ventilation!
In case of momentary power failure, reduce the load and keep a medium heat.
Devices without ventilation MUST be decompressed in opening the two hot air outlet
and fixing 2 ducts of at least 1 meter (on the right and left side of the fireplace).
-
The fireplace is designed to a door-closed use, after starting the fire. Reload when only
glowing embers remain.
-
We advise you to use fire starter cube which facilitate a quicker and cleaner wood
combustion.
-
Do not use inflammable liquid products.
Combustion
Combustion air
Combustion air is settled by an automatic thermostat, which regulate the working speed of
your fireplace, after started.
Thanks to the temperature sensor (on the right side of the device), the thermostat
automatically settle the coming of air, by opening of closing the air inlet. The thermostat is
not influenced by the room temperature. It only settles the one of the fireplace (which will
depends on the speed of the fans). It is therefore normal that if the temperature of the
fireplace is high, the valve will be closed whatever the control switch and the temperature of
the room are.
For fireplaces with manual thermostat, it is up to you to set the air inlet according to the
desired heat.
Convection air
Originally, your appliance operates with ventilation controlled by a speed controller and an
airstat. Depending on the chosen position, the speed controller determines the forced hot
air flow outside your fireplace (maximum power heating is reached with ventilation on the
highest level).
The airstat (on the left side of the device) is an accessory which turns on and off ventilation
according to temperature sensor. This ventilation turns on once the fireplace has reached a
certain temperature. Ventilation must always turn when the fireplace is hot, otherwise the
fans will be degraded. Hot air outlet will allow a hot convection air distribution in the room