5. MOUNTING ASSEMBLY OF SYSTEM.
- Place the CICLON CC in the concealed cistern frame, and the set in a suitable place and connect
every inlet and outlet (see connection figure on page 10). Provide a one meter minimum distance
from the flush to the waste disposer, so that it can operate during the appropriate time to eliminate
the wastes effectively.
- Check the frame position onto the building
structure, adjust its height, so the base of the
macerator body is aligned with the final floor
finished height. Mark drilling points in the back
wall or the light wall structure.
- Verify all the components of the concealed
cistern, flushing mechanism, float valve, stop
cock, to check they remain in place and not
moved from transport.
- Mount the stopcock in the tank (1/2”), select the
hole depending on water supply position.
- Screw the frame module to the floor and to the
wall or light structure
.
- Prepare the electrical connection before tiling or
closing light wall structure
.
-
A normalized IEC electrical base is
recommended to be installed in case
disassembling is needed.
- Install water supply to the ½” supplied inlet and
verify it does not leak
.
-
Install protection covers when tiling on
discharge pipe from the tank and waste pipe
from the lavatory to the sanitary macerator unit
until works are finished and the lavatory
installed.
- Thread wall-hung fixing bolts and protect them
(covers supplied)
.
- Install the selected frontal finishing onto the
concealed cistern (light wall, tiling). Keep register indicated areas (440x310 mm for the bottom,
magnets, push plate). Cutting form is supplied.
- Cut straight pan connector & lavatory water supply
to the required length. Connect both to the
toilet and fix them on the concealed cistern. Verify their correct adjustment free of leakage.
- The CICLON CC waste disposer has 2 lateral auxiliary inlets, by means of a 1 1/2 “ side connection
provided with non-return
valve and a top auxiliary inlet (1 ½”) to connect a single sanitary appliance
in each. If the side auxiliary inlet is not used, there is a plug to leave it out of action. The unit receives
water from the sanitary appliance by the action of gravity. The horizontal stretch from the waste
disposer must have a positive slope (1%-2%) to allow drainage when the waste disposer is not working.
- When a shower base is connected to the waste disposer, it is essential to provide a minimum height
of 180 mm between the lower part of the shower base and the waste disposer base, thus providing
the necessary slope towards the waste inlets.
- It is recommended to use a non-syphonic waste pipe when installing the shower base and the
bathtub; otherwise, see figure on page 13 to install a secondary ventilation system
22 - INSTRUCTIONS AND MAINTENANCE GUIDE
T-604 CC WASTE DISPOSER
English
Español
Summary of Contents for Ciclon CC T-604 CC
Page 34: ...34 INSTRUCTIONS AND MAINTENANCE GUIDE T 604 CC WASTE DISPOSER 12 INSTALLATION English Espa ol...
Page 35: ...MANUAL DE INSTRUCCIONES Y MANTENIMIENTO 35 T 604 CC WASTE DISPOSER English Espa ol...
Page 36: ...36 INSTRUCTIONS AND MAINTENANCE GUIDE T 604 CC WASTE DISPOSER 12 MAINTENANCE English Espa ol...