26
Operation and maintenance manual
IIn the selected option we set up the correct value and
we
validate…
Once the last question is answered, the Filtmaster filter
cleaning controller is ready to work according to the set-
up program.
In the selected option we set up the correct value and we
validate…
FLUSH TIME
00m 05s
PAUSE TIME
00m 04s
FLUSH TIME
FILTER : 01 00m 05s
PAUSE TIME
FILTER : 01 00m 04s
Deleting
At any moment the initial values can be re-established by
pressing
F
in the STATUS SCREEN.
Special situations
If there is an electric voltage drop, the Filtmaster filter
cleaning controller keeps all the data in its memory until
the electrical voltage recovers. Then, the controller con-
tinues working from the last status (after waiting progra-
med DELAY AFTER FLUSHING time).
If a cleaning is being done in the TIME / VOLUME mode
and the filtration system stops, when it restarts, a DELAY
AFTER FLUSHING time passes and then it continues
with the same cleaning process.
Warranty
JIMTEN, S.A., warrants this controller against any defect
in materials for a period of two (2) years from the date
of purchase.
We will replace, free of charge, the defective part or parts
found to be defective under normal use.
We reserve the right to inspect the defective part prior to
replacement.
JIMTEN, S.A., grants this warranty if the filtering insta-
llation and due maintenance are done according to our
technical recommendations.
Limit of responsibility
JIMTEN, S.A., does not cover as warranty (unless agreed
otherwise) the following:
• Civil works.
• Hydraulic or electrical connections.
• Additional technical visits to be done for reasons not
attributable to JIMTEN SA (no water, no power, absen-
ce of the customer, etc).
• Anything not specified in the Warranty Section.
By pressing
we change answer to YES. We press
to validate and
to exit this option.
Limit of
responsibility
11
RESET TO DEFAULT
VALUES?: NO