This document is only for internal use of JINNENG CLEAN ENERGY TECHNOLOGY LTD, and shall not be published or
copied without permission of the company.
4
)
210 Module
Fixture fixed installation method
Installation of cross beam through long side four pressure blocks
Static load
(
Test load
)
Installation Method
Module Type
Installation of cross beam through long side
four pressure blocks
JNMM120-XXX
+5400Pa/-2400Pa
JNBM120-XXX
+5400Pa/-2400Pa
JNMM132-XXX
+5400Pa/-2400Pa
JNBM132-XXX
+5400Pa/-2400Pa
Table 11
Each aluminum mounting clamp comes with an M8 bolt, a plain washer, a spring washer, and an
M8 nut. To fasten the module:
1. Place the module on the two supporting bars (not provided). The bars should be made with
stainless material or treated with an anti-corrosion process (e.g., anodic oxidation treatment). The
component must be parallel or laid across support rods (the width of the support rod is 40-80 mm).
2.
The bar’s top surface contacted with module frame should come with grooves compatible with an
M8 bolt.
3. If the bars do not come with grooves, holes of a suitable diameter may need to be drilled to allow
bolts to be attached to the bars at the same locations as mentioned before.
4. Secure each clamp by attaching plain washer, spring washer, and nut, in that order.
5. Both of close-ups of Fig. b indicate the middle clamps and Fig. c indicate the side clamps for your
reference. The dimensions for the middle clamps are
a ≥ 40 mm, b ≥ 26 mm, c = 8 mm, d ≥ 28 mm,
and Ø = 9 mm. The torque for tightening the nut and bolts recommended 28Nm when the property
class of bolts and nuts is Class 8.8.
Especially the installation method of cross beam through long
side briquetting, slide bolts through groove on the supporting bars next to the locations where the
clamps are to be fastened. The module may be clamped only in the permitted clamping area as on
the long edge of the frame, and the edge of the clamp should not coincide with the position of the
mounting hole.