This document is only for internal use of JINNENG CLEAN ENERGY TECHNOLOGY LTD, and shall not be published or
copied without permission of the company.
2. Clean the water pressure cannot be more than 690 Kpa.
3. For stubborn dirt on the glass surface, you can use mild, non -abrasive cleaners, such as
glass cleaners, alcohol, etc., and do not use corrosive chemical reagents.
4. People can clear it with soft items if there is thick snow on the glass , be careful to not scratch
glass. It is not recommended to clean when the snow wait to be too thick , to avoid the module
surface freeze.
5. Do not clean the module which glass is cracked or cable is damaged, as there is a risk of
electric shock.
6. Don
’t walking, standing or sitting on the module to clean.
7. It is not recommended to clean with higher mineral water because there are remaining
minerals after dry up.
8. It is forbidden to clean with water which temperature is different largely with module
,
otherwise the glass is impossible to broken.
9. Do not touch the surface of module with bare hands.
6.3 Safety tips
1.
It is recommended that professional personnel check and maintain the power station system
to avoid electric shock or personal injury.
2.
Pay attention to safety protection measures during inspection and maintenance. Electrical
equipment may be in high voltage danger.
3.
Follow the operation and maintenance instructions and safety rules for all components used
in PV system.
7 Unloading and storage of modules
7.1 Unloading
7.1.1 Horizontal - container loading
S/N
Operating Procedure
Photo
Control Point