- 6

 

-

 

 

2.2 Installation Condition 

 

2.2.1 Climate condition 

Please install the modules in the following conditions: 

a)  Operating temperature: within 

–40°C(-4

°

F) to 85°C (185

°

F) 

b)  Humidity: < 85RH%. 

 

Note: The mechanical load bearing (include wind and snow loads) of the module is 

based  on  the  mounting  methods.  The  professional  system  installer  must  be 
responsible for mechanical load calculation according to the system design. 
 

2.2.2 Site selection 

In most applications, Jinko Solar PV modules should be installed in a location where 
they will receive maximum sunlight throughout the year. In the Northern Hemisphere, 
the module should typically face south, and in the Southern Hemisphere, the modules 
should  typically  face  north.  Modules  facing  30  degrees  away  from  true  South  (or 
North) will lose approximately 10 to 15 percent  of  their power output. If  the module 
faces 60 degrees  away  from true South  (or North),  the  power  loss  will  be  20  to 30 
percent. 
When  choosing  a  site,  avoid  trees,  buildings  or  obstructions,  which  could  cast 
shadows on the solar photovoltaic modules especially during the winter months when 
the  arc  of  the  sun  is  lowest  over  the  horizon.  Shading  causes  loss  of  output,  even 
though the factory fitted bypass diodes of the PV module will minimize any such loss. 
Do not install the PV module near naked flame or flammable materials. 
When solar modules are used to charge batteries, the battery must be installed in a 
manner, which will protect the performance of the system and the safety of its users. 
Follow  the  battery  manufacturer’s  guidelines  concerning  installation,  operation  and 
maintenance  recommendations.  In  general,  the  battery  (or  battery  bank)  should  be 
away  from  the  main  flow  of  people  and  animal  traffic.  Select  a  battery  site  that  is 
protected  from  sunlight,  rain,  snow,  debris,  and  is  well  ventilated.  Most  batteries 
generate hydrogen gas when charging, which can be explosive. Do not light matches 
or create sparks near the battery bank. When a battery is installed outdoors, it should 

Summary of Contents for JKM200M-60

Page 1: ...JinkoSolar Photovoltaic Module User Manual UL1703 ...

Page 2: ...stallation safety 2 2 Installation Condition 2 3 Mechanical Installation introduction 2 2 1 Climate condition 2 2 2 Site selection 2 3 1 Fixation with screws 2 3 2 Fixation with clamps 2 2 3 Tilt angle selection 3 Wiring and connection 4 Maintenance and care 5 Electrical specification 6 Disclaimer of Liability 25 7 Contact us Edition 10 2015 ...

Page 3: ... UL1000V JKMxxxP 60 JKMxxxPP 60 JKMxxxP 60B JKMxxxPP 60B JKMSxxxP 60 JKMSxxxPP 60 JKMxxxPP 60 Plus XXX 200 265 in increment of 5 JKMxxxP 72 JKMxxxPP 72 JKMxxxP 72B JKMxxxPP 72B JKMSxxxP 72 JKMSxxxPP 72 JKMxxxPP 72 Plus XXX 250 320 in increment of 5 JKMxxxM 60 JKMxxxM 60B JKMSxxxM 60 XXX 200 280 in increment of 5 JKMxxxM 72 JKMxxxM 72B JKMSxxxM 72 XXX 250 320 in increment of 5 Make sure the array o...

Page 4: ...isted mounting system that has been rated as a Class A System when installed with type 1 modules is suitable to maintain the System Class A Fire Rating in America Module model Specific construction Marking All Superstrate 3 2 4 0 mm thick EVA 0 25 0 6 mm thick Substrate 0 34 mm 0 385 mm thick Frame Types 40mm by 20mm or 40mm by 35mm or 700 0218 Module Fire Performance Type 1 1 3 Warnings PV module...

Page 5: ...it is electrically grounded in accordance with the instructions presented below and the requirements of the National Electrical Code Any module without a frame laminate shall not be considered to comply with the requirements of UL 1703 unless the module is mounted with hardware that has been tested and evaluated with the module under this standard or by a field Inspection certifying that the insta...

Page 6: ...ule is likely to experience conditions that produce more current and or voltage than reported at standard test conditions The requirements of the National Electrical Code NEC in Article 690 shall be followed to address these increased outputs In installations not under the requirements of the NEC the value of Isc and Voc marked on this module should be multiplied by a factor of 1 25 when determini...

Page 7: ...ck all connections The interconnect cable should be securely fastened to the module frame Cable support should be done in a way to avoid the connector from scratching or impacting the back sheet of the module Do not touch the junction box and the end of the interconnect cables connectors with bare hands during installation or under sunlight regardless of whether the PV module is connected to or di...

Page 8: ... power loss will be 20 to 30 percent When choosing a site avoid trees buildings or obstructions which could cast shadows on the solar photovoltaic modules especially during the winter months when the arc of the sun is lowest over the horizon Shading causes loss of output even though the factory fitted bypass diodes of the PV module will minimize any such loss Do not install the PV module near nake...

Page 9: ...f the PV modules should be selected to optimize the performance based on seasonal load and sunlight In general if the PV output is adequate when irradiance is low e g winter then the angle chosen should be adequate during the rest of the year For grid connected installations where the PV modules are attached to a permanent structure PV modules should be tilted so that the energy production from th...

Page 10: ...r downward pressure of 3600Pa and negative or upward pressure of 1600Pa When mounting modules in snow prone or high wind environments Special care should be taken to mount the modules in a manner that provides sufficient design strength while meeting local code requirements 4 Where common grounding hardware nuts bolts star washers spilt ring lock washers flat washers and the like is used to attach...

Page 11: ... be attached to a mounting rail using M8 corrosion proof screws together with spring washers and flat washers in eight symmetrical locations on the PV module The applied torque value should be big enough to fix the modules steadily The reference value for M8 screw is 16 20N m As to special support system or special installation requirement please reconfirm with the support s supplier for the torqu...

Page 12: ...his type of clamp mounting method please be sure to use at least four clamps on each module two clamps should be attached on each long side of the module The applied torque value should be big enough to fix the modules steadily Please consult with the clamp or support s supplier for the specific torque value Please find detailed mounting information in the below illustration the mounting place dis...

Page 13: ...at long side with Clamp 3 Wiring and connection a Before this procedure please read the operation instructions of the PV system carefully Make wiring by Multi connecting cables between the PV modules in series or parallel connection which is determined by user s configuration requirement for system power current and voltage b PV module connected in series should have similar current and modules mu...

Page 14: ...ting racks must be properly grounded in accordance with local and national electrical codes It is recommended that the applied torque is 2 3 to 2 8Nm Jinko modules can be grounded using third party ground washers or clip devices Use Tyco 1954381 1 as long as the products are approved for grounding metallic frames of PV modules Alternate grounding options built into the racking system are acceptabl...

Page 15: ...ite conditions using a soft cloth dry or damp as necessary b Never use abrasive material under any circumstances c Examine the PV module s for signs of deterioration Check all wiring for possible rodent damage weathering and that all connections are tight and corrosion free Check electrical leakage to ground d Check fixing screws and mounting brackets are tight adjust and tighten as necessary e Ch...

Page 16: ...radiance with AM 1 5 spectrum and 25 deg 77 F ambient temperature The module might produce more or less voltage or current than rating value in uncertainty condition Tables below are electrical characteristics of PV products at STC and the tolerance of Isc Voc Vmp and Imp is 3 except that JKMSxxxM 60 JKMSxxxM 72 series is 10 ...

Page 17: ...5 320 Maximum Power Voltage Vmp V 34 2 34 5 34 7 34 9 35 0 35 2 35 3 35 5 35 8 36 2 36 6 36 8 37 0 37 2 37 4 Maximum Power Current Imp A 7 31 7 39 7 49 7 59 7 71 7 81 7 93 8 03 8 11 8 15 8 20 8 30 8 38 8 48 8 56 Open circuit Voltage Voc V 43 5 43 7 43 9 44 1 44 2 44 4 44 5 44 7 44 9 45 1 45 3 45 6 45 9 46 2 46 4 Short circuit Current Isc A 8 05 8 18 8 26 8 33 8 43 8 49 8 58 8 61 8 69 8 76 8 84 8 9...

Page 18: ... Vmp V 34 8 35 0 35 3 35 6 35 9 36 1 36 3 36 5 36 7 36 8 37 0 37 2 37 4 37 6 37 8 Maximum Power Current Imp A 7 18 7 29 7 37 7 44 7 52 7 62 7 71 7 81 7 90 8 02 8 11 8 20 8 29 8 38 8 47 Open circuit Voltage Voc V 43 4 43 6 43 9 44 1 44 4 44 6 44 8 45 0 45 2 45 3 45 5 45 7 45 9 46 1 46 3 Short circuit Current Isc A 7 84 7 92 7 99 8 07 8 15 8 23 8 32 8 40 8 47 8 55 8 64 8 72 8 80 8 87 8 95 Maximum sy...

Page 19: ...255 260 265 Maximum Power Voltage Vmp V 28 2 28 4 28 6 28 8 29 0 29 2 29 4 29 6 29 8 30 1 30 5 30 8 31 1 31 4 Maximum Power Current Imp A 7 09 7 22 7 34 7 47 7 59 7 71 7 82 7 94 8 06 8 14 8 20 8 28 8 37 8 44 Open circuit Voltage Voc V 35 3 35 5 35 8 36 1 36 3 36 6 36 8 37 0 37 3 37 5 37 7 38 0 38 1 38 6 Short circuit Current Isc A 8 09 8 18 8 25 8 31 8 41 8 48 8 56 8 65 8 71 8 76 8 85 8 92 8 98 9 ...

Page 20: ... 4 28 6 28 8 29 0 29 2 29 4 29 6 29 8 30 1 30 5 30 8 30 9 31 2 31 4 31 6 31 8 Maximum Power Current Imp A 7 09 7 22 7 34 7 47 7 59 7 71 7 82 7 94 8 06 8 14 8 20 8 28 8 42 8 50 8 60 8 70 8 81 Open circuit Voltage Voc V 35 3 35 5 35 8 36 1 36 3 36 6 36 8 37 0 37 3 37 5 37 7 38 0 37 9 38 2 38 4 38 5 38 6 Short circuit Current Isc A 8 09 8 18 8 25 8 31 8 41 8 48 8 56 8 65 8 71 8 76 8 85 8 92 9 10 9 19...

Page 21: ...tage Vmp V 32 5 32 8 33 0 33 2 33 3 33 4 33 5 33 7 34 0 34 4 34 8 34 9 35 2 35 3 35 5 Maximum Power Current Imp A 7 69 7 78 7 88 7 99 8 12 8 22 8 35 8 45 8 54 8 58 8 63 8 74 8 82 8 93 9 01 Open circuit Voltage Voc V 41 3 41 5 41 7 41 9 42 0 42 2 42 3 42 5 42 7 42 8 43 0 43 3 43 6 43 9 44 1 Short circuit Current Isc A 8 52 8 61 8 70 8 77 8 87 8 94 9 03 9 06 9 15 9 22 9 31 9 38 9 43 9 48 9 53 Maximu...

Page 22: ...5 0 35 3 35 6 35 9 36 1 36 3 36 5 36 7 36 8 37 0 37 2 37 4 37 6 37 8 Maximum Power Current Imp A 7 18 7 29 7 37 7 44 7 52 7 62 7 71 7 81 7 90 8 02 8 11 8 20 8 29 8 38 8 47 Open circuit Voltage Voc V 43 4 43 6 43 9 44 1 44 4 44 6 44 8 45 0 45 2 45 3 45 5 45 7 45 9 46 1 46 3 Short circuit Current Isc A 7 84 7 92 7 99 8 07 8 15 8 23 8 32 8 40 8 47 8 55 8 64 8 72 8 80 8 87 8 95 Maximum system Voltage ...

Page 23: ...er Voltage Vmp V 26 8 27 0 27 2 27 4 27 6 27 2 27 9 28 1 28 3 28 6 29 0 29 3 29 5 29 8 Maximum Power Current Imp A 7 46 7 60 7 73 7 86 7 98 8 12 8 23 8 36 8 48 8 57 8 63 8 72 8 81 8 88 Open circuit Voltage Voc V 33 5 33 7 34 0 34 3 34 5 34 8 35 0 35 2 35 4 35 6 35 8 36 1 36 2 36 7 Short circuit Current Isc A 8 53 8 61 8 68 8 75 8 85 8 92 9 01 9 10 9 17 9 23 9 32 9 39 9 45 9 51 Maximum system Volta...

Page 24: ...8 29 0 29 2 29 4 29 6 29 8 30 1 30 5 30 8 30 9 31 2 31 4 31 6 31 8 Maximum Power Current Imp A 7 09 7 22 7 34 7 47 7 59 7 71 7 82 7 94 8 06 8 14 8 20 8 28 8 42 8 50 8 60 8 70 8 81 Open circuit Voltage Voc V 35 3 35 5 35 8 36 1 36 3 36 6 36 8 37 0 37 3 37 5 37 7 37 9 38 0 38 2 38 4 38 5 38 6 Short circuit Current Isc A 8 09 8 18 8 25 8 31 8 41 8 48 8 56 8 65 8 71 8 76 8 85 8 92 9 10 9 19 9 28 9 40 ...

Page 25: ...sumed by Jinko for any infringement of patents or other rights of third parties which may result from use of the PV product NO license is granted by implication or otherwise under any patent or patent rights The information in this manual is based on Jinko s knowledge and experience and is believed to be reliable but such information including product specification without limitations and suggesti...

Page 26: ... 24 Note ...

Page 27: ...100 Tel 86 793 8588188 Fax 86 793 8461152 Jinko solar Import and Export co LTD Xuri District Shangrao Economic Development Zone Jiangxi Province CHINA Postcode 334100 Tel 86 793 8618987 Fax 86 793 8461152 Customer Service cs jinkosolar com Jinko Solar USA 495 Market Street Suite 2200 San Francisco CA 94105 Tel 415 402 0502 Fax 415 402 0703 us jinkosolar com Jinko Solar Canada Co Ltd Suite 703 100 ...

Page 28: ... com After sales cs jinkosolar com Global Sales Marketing Center No 1 Jinko Road Shangrao Economic Development Zone Jiangxi Province China 334100 Tel 86 793 858 8188 Fax 86 793 846 1152 Jiangxi Manufacture Base No 58 Yuanxi Road Haining Yuanhua Industrial Park Zhejiang Province China 314416 Tel 86 573 8798 5678 Fax 86 573 8787 1070 Zhejiang Manufacture Base ...

Reviews: