Rev. C
- 7
-
be placed in an insulated and ventilated battery case specifically designed for the
purpose.
Do not install the PV module in a location where it would be immersed in water or
continually exposed to water from a sprinkler or fountain etc.
2.2.3 Tilt angle selection
The tilt angle of the PV module is measured between the surface of the PV module
and a horizontal ground surface (Figure 1). The PV module generates maximum
output power when it faces the sun directly.
Figure1: PV module title angle
For standalone systems with batteries where the PV modules are attached to a
permanent structure, the tilt angle of the PV modules should be selected to optimize
the performance based on seasonal load and sunlight. In general, if the PV output is
adequate when irradiance is low (e.g., winter), then the angle chosen should be
adequate during the rest of the year. For grid-connected installations where the PV
modules are attached to a permanent structure, PV modules should be tilted so that
the energy production from the PV modules will be maximized on an annual basis.
Only for UL listed products -
The System Fire Class Rating of the module or panel in a mounting system in
combination with a roof covering complete with requirements to achieve the specified
System Fire Class Rating for a non-BIPV module or panel.
Any module or panel mounting system limitations on inclination required to maintain a
specific System Fire Class Rating.