PAGE 138 of 177
The blinking highlighted box indicates the current selection. Use the click
knob or
Up
and
Down
buttons to select different settings.
Press
Edit
to enter the
Edit
screen to apply changes to the selected setting.
The
Exit
button directs to the
System Utilities
screen.
TITLE
DESCRIPTION
VALID
RANGE
DEFAULT
Units In=0/MM=1
Changes the measurement units for display
and user entry. When set to 0, units measure
in inches. When set to 1, units measure in
millimeters.
0-1
1
Scan Steering
%max
Sets the steering limit maximum when using
the jog mode scan setting. Lower values
make the steering joystick less sensitive
and more accurate enabling better control
following a guide or feature. Units are a
percentage of the maximum system allowed.
0-100
100
Rapid Steering
%max
Sets the steering limit maximum when
using the Rapid setting within Jog mode.
Recommended to be left at 100 to allow
maximum crawler maneuverability.
0-100
100
Crawler Scan
unit/s
Sets the crawler scan rate in the current
units/second. This setting can also be
changed through the Jog or Two Axis Scan
Speed screens
0-254 mm/s
(0-10 in/s)
76 mm/s
(3.0 in/s)
Crawler Rapid
unit/s
Sets the crawler rapid rate in the current
units/second. This setting can also be
changed through the Jog screen.
0-254 mm/s
(0-10 in/s)
254 mm/s
(10 in/s)
Steering Bias +/-%
Sets a steering bias for the steering joystick
which may be turned on and off in jog
mode. Setting this setting to anything other
than 0 will show the bias button on the Jog
screen. Steering bias allow the operator to
set a fixed steering value when the steering
joystick is in its neutral position.
0
-30 to +30
6.2.6.2 Diagnostics Screens
Several diagnostic screens allow various system functions to be monitored.
Navigate to different diagnostic screens using the
PREV
and
NEXT
buttons.
The
Exit
button returns to the
System Utilities
screen.