PAGE 106 of 142
6.3.6.1 User Settings Screen
Allows user to customize the system to their preferences.
The blinking highlighted box indicates the current selection. Use the click
knob or
Up
and Down buttons to select different settings.
Press
Edit
to enter the
Edit
screen to apply changes to the selected
setting.
The
Exit
button direct to the
System Utilities
screen.
Title
Description
Valid Range Default
Units
Changes the measurement units for
display and user entry. When set to 0, units
measure in inches. When set to 1, units
measure in millimeters.
inches or
mm
mm
Crawler Scan
Sets the crawler scan rate in the current
units/second. This setting can also be
changed through the Jog or Two Axis Scan
Speed screens
5-142 mm/s
(0.2-5.6 in/s)
43 mm/s
(1.7 in/s)
Crawler Rapid
Sets the crawler rapid rate in the current
units/second. This setting can also be
changed through the Jog screen.
5-142 mm/s
(0.2-5.6 in/s)
142 mm/s
(5.6 in/s)
Display
Brightness
Sets the brightness of the display.
0-100
100%
User Settings
1
Exit
Edit
Units
mm
%
%
mm/s
mm/s
mm/s
mm/s
%
Scan Steering
30
30
5
142
0
0
Disabled
0
Rapid Steering
Crawler Scan
Crawler Rapid
Raster Scan
Raster Rapid
Raster Flip
Steering Bais
Fig. 237 - User settings screen