is used toEnter and Exit menu or function setting; INC key is used to plus
1 at a time to the parameter needs setting; DEC key is used to minus 1 at
a time to the parameter needs setting;
Ⅱ
. Enter and Exit Menu Setting
1. Enter menu: Press SET key, loose the key after hearing a sound “du”,
“P00” appears, which indicates the status of menu setting. Now press INC
key Or DEC key to the parameter needs setting: Press INC key to plus 1,
and press DEC key to minus 1. There are 15 kinds of functions as below:
P00: Exit from menu setting, when P00 appears, press SET key to exit menu.
P01: The motor running direction when power on, =000 means clockwise
rotation, and =001 meansanticlockwise rotation.
P02: The longest operation time of barrier.Its measurement is 0.1sec, when we
set itto 60, the time is 6 seconds. If the barrier hasn't closed in 6 sec, it will
automatically stop.(System default is 60)
P03: The passing time, measurement is second. Number 10 means 10 seconds. If
the pedestrian hasn't passed through the gate in pre-set time, the passing
right will be canceled.( System default is 10)
P04: Working mode(System default is 000)
=000 bi-direction swiping card
=001 swipe card enter but free for exit
=002 free for entrybut swipe card exit
=003 free for entry and exit
=004swipe card for entry only (single direction)
=005 swipe card for exit only (single direction)
P05: The speed of barrier gate opening for entry, system default is 10.
P06: The speed of barrier gate closing after entry, system default is 10.
P07: The speed of barrier gate opening for exit, system default is 10
P08: The speed of barrier gate closing after exit, system default is 10.
P09: Pedestrian who pass through the channel in the pre-set time will be
regarded as one person, system default is 10.
P10: Counter clear for entry , when it displays P10, press SET Key, then it
displays O-L, press INC Key to clear the counter.
P11: Counter clear for exit, when it displays P11, press SET Key, then it displays