is used toEnter and Exit menu or function setting; INC key is used to plus
1 at a time to the parameter needs setting; DEC key is used to minus 1 at
a time to the parameter needs setting;

. Enter and Exit Menu Setting

1. Enter menu: Press SET key, loose the key after hearing a sound “du”,

“P00” appears, which indicates the status of menu setting. Now press INC
key Or DEC key to the parameter needs setting: Press INC key to plus 1,
and press DEC key to minus 1. There are 15 kinds of functions as below:

P00: Exit from menu setting, when P00 appears, press SET key to exit menu.
P01: The motor running direction when power on, =000 means clockwise

rotation, and =001 meansanticlockwise rotation.

P02: The longest operation time of barrier.Its measurement is 0.1sec, when we

set itto 60, the time is 6 seconds. If the barrier hasn't closed in 6 sec, it will
automatically stop.(System default is 60)

P03: The passing time, measurement is second. Number 10 means 10 seconds. If

the pedestrian hasn't passed through the gate in pre-set time, the passing
right will be canceled.( System default is 10)

P04: Working mode(System default is 000)

=000 bi-direction swiping card
=001 swipe card enter but free for exit
=002 free for entrybut swipe card exit
=003 free for entry and exit
=004swipe card for entry only (single direction)
=005 swipe card for exit only (single direction)

P05: The speed of barrier gate opening for entry, system default is 10.
P06: The speed of barrier gate closing after entry, system default is 10.
P07: The speed of barrier gate opening for exit, system default is 10
P08: The speed of barrier gate closing after exit, system default is 10.
P09: Pedestrian who pass through the channel in the pre-set time will be

regarded as one person, system default is 10.

P10: Counter clear for entry , when it displays P10, press SET Key, then it

displays O-L, press INC Key to clear the counter.

P11: Counter clear for exit, when it displays P11, press SET Key, then it displays

Summary of Contents for JKDC-100C

Page 1: ...J K D C S E C U R I T Y C O L I M I T E D 1 Swing Gate User Manual JKDC 100C...

Page 2: ...nd various consumption devices 2 Features and Functions 1 SUS304 stainless steel rainproof case 2 LINIX the best micro motor brand in China brush less DC motor is used and its surface is plated with d...

Page 3: ...pecifications 4 Control Interface 1 Equipment controlling connection method For two way relay and switch signal The COM connect to the VDD from Gate Opening interface The NO signal need to connect to...

Page 4: ...ina Web http www securityjkdc com Tel 86 755 28408621 4 Note Before using please make sure ground wire connected prohibit taking electricity from the main board Wiring Diagram Menu Setting I Display a...

Page 5: ...et itto 60 the time is 6 seconds If the barrier hasn t closed in 6 sec it will automatically stop System default is 60 P03 The passing time measurement is second Number 10 means 10 seconds If the pede...

Page 6: ...using The covers are made by 10mm thick PVC materials On the standard decorative cover the words Please put in your card here are printed using silk screen printing method The background of the decora...

Page 7: ...f the specific layout environment and power supply conditions propose reasonable design schemes to customers striving for best price value 2 Sales Service A Assemble and adjust the equipment system to...

Page 8: ...ior aftersales service support If any question arises in the operation please call the service support hot line of our company Our engineer will be glad to answer your questions Thanks again for your...

Page 9: ...uch as fire earthquake etc b Any failure arising from improper operation not satisfying requirements or from use under unaccepted working environment and conditions c Any failure arising from the repa...

Reviews: