7. Operating Instructions (Wiring Diagram Attached):
The Tripod Turnstile has three different operating modes:
1) Always Free Passing (Barrier Free Passage)
2) Mechanical Entry Control (Manual Unidirectional Passage)
3) Electric Driving Entry Control (Intelligent Passage through Identification by means of IC, ID,
Bar-code, etc.)
Each of the above three operating modes has an emergency design: when there is a power failure,
the tripod bar at the level position will automatically drop to ensure free passage through the
turnstile. (Satisfying requirements of fire control security).
4) After you fix the turnstile at the installation site (refer to the following installation diagram),
firstly connect AC220V power supply to the switch-mode power supply (L-AC, N-AC), and
connect ground wire to PG pole. Switch on the power supply and check if the power indicator
light (LED on the control board) is on. Find the test buttons (S1, S2) on the control board, and
then check if the indicating direction of the indicator light is correct, and if the turnstile bar can
turn. If the indicator light is ok and the turnstile can turn, it means the turnstile is ready for normal
operation.
5) Connecting access controller: Put the controller on the mounting plate of the turnstile and fix it,
connect it to the card reader and power supply, and then connect the controller
’
s electric lock
output terminal to the PASS1. PASS2 terminal or DOOR1, DOOR2 terminal of the control board.
(If the electric lock terminal is a dry contact, connect the terminal to PASS1. PASS2; if the
electric lock is of DC12V output, connect the terminal to DOOR1, DOOR2. )
Note: The DC12V input of the access controller must not be connected to the
PASS1.PASS2 terminal of the control board.
6) Networking of access controller: (To be carried out by the customer)