33
I. PREPARATION FOR OPERATION/START-UP
The following items
should be
checked before attempting to operate the dryer:
1. Read
ALL
“
CAUTION,
” “
WARNING,
” and “
DIRECTION
” labels attached to the dryer.
2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label, which is
located on the left side panel area behind the top control (access) door.
3.
GAS MODELS
- check to assure that the dryer is connected to the type of heat/gas indicated on the dryer
data label.
4.
GAS AND ELECTRIC MODELS
- the sail switch damper assembly was installed and adjusted at the
factory prior to shipping. However, each sail switch adjustment
must be
checked to assure that this
important safety control is functioning.
5. Check bolts, nuts, screws, terminals, and fittings for tightness and security.
6.
GAS MODELS
- be sure that
ALL
gas shutoff valves are in the open position.
7. Check
ALL
back guard panels and service box covers have been replaced.
8. Check the lint drawer to assure that it is closed and secured in place.
9. Rotate the basket (tumbler/drum) by hand to be sure it moves freely.
10.
STEAM MODELS
- check to insure that a clean, dry, regulated air supply (80 psi [5.51 bar]) is on the
dryer (with air-operated damper system only).
11.
STEAM MODELS
- check to insure
ALL
steam shutoff valves are open.
12.
STEAM MODELS
- check steam damper operation.
13. Check basket (tumbler) bearing setscrews to insure that they are
ALL
tight.
14. Check that vent is connected to the dryer and is exhausted to the outdoors.