SECTION 7 - JLG CONTROL SYSTEM
7-14
– JLG Lift –
3121222
7.7
ELEVATION SENSOR CALIBRATION
1.
Be sure that the machine is parked and stowed on
level ground.
2.
Attach the analyzer near the ground control sta-
tion.
3.
Go to Access Level 1 and scroll through to CALI-
BRATION.
4.
Under Calibrations go to SET ELEV SENSOR.
5.
Press enter for Yes and the Elevation Sensor will
set.
NOTE:
Check the elevation sensor by lifting the scissor arms,
from the platform, and driving until the drive speed
cuts back. Refer to the Maximum High Drive Cut Out
Height table in section 1 of this manual for proper
speed cut out height.