SECTION 5 - CONTROL COMPONENTS
5-2
– JLG Lift –
3121222
5.2
CONTROL COMPONENTS - SERVICE
Main Power Contactor Relay
The main power contactor relay is located on the bulk-
head on the right-front, inside the compartment as
shown following.
Elevation Limit Switch
Ground Alarm
Warning Beacon - Frame Mounted
Main Power Relay - Installation
1.
Main Power Relay
2.
Attach Screws
Note:
See (See Figure 5-1.) for electrical wiring connections.
Elevation Limit Switch - Installation
1.
Attach Screws
2.
Elevation Limit Switch
3.
Switch Mounting Block
4.
Mounting Holes in Frame
5.
Attach Nuts
Note:
Located on right-front of machine frame behind drive wheel assembly
next to mast.
Ground Alarm - Installation
1.
Ground Alarm
2.
Attach Screws
Note:
Remove the charger/step-plate cover on the rear of the machine,
mounted just above the battery charger.
Warning Beacon - Installation
1.
Beacon Assembly
2.
Attach Screws
Note:
Located on base frame just above the left rear wheel.
Summary of Contents for 1230ES
Page 1: ...AS NZS Service and Maintenance Manual Model s 1230ES P N 3121222 June 22 2017 ...
Page 2: ...NOTES ...
Page 24: ...SECTION 1 MACHINE SPECIFICATIONS 1 12 JLG Lift 3121222 NOTES ...
Page 32: ...SECTION 2 GENERAL SERVICE INFORMATION 2 8 JLG Lift 3121222 NOTES ...
Page 78: ...SECTION 4 BASE COMPONENTS 4 40 JLG Lift 3121222 NOTES ...
Page 104: ...SECTION 5 CONTROL COMPONENTS 5 26 JLG Lift 3121222 NOTES ...
Page 158: ...SECTION 8 DIAGNOSTIC TROUBLE CODES 8 22 JLG Lift 3121222 NOTES ...
Page 198: ...SECTION 9 GENERAL ELECTRICAL INFORMATION SCHEMATICS 9 40 JLG Lift 3121222 ...
Page 199: ...SECTION 9 GENERAL ELECTRICAL INFORMATION SCHEMATICS 3121222 JLG Lift 9 41 ...
Page 200: ...SECTION 9 GENERAL ELECTRICAL INFORMATION SCHEMATICS 9 42 JLG Lift 3121222 ...
Page 202: ...SECTION 9 GENERAL ELECTRICAL INFORMATION SCHEMATICS 9 44 JLG Lift 3121222 NOTES ...