SECTION 3 - MACHINE CONTROLS AND INDICATORS
3121261
– JLG Lift –
3-19
Platform Control Indicator Panel
(See Figure 3-5., Platform Control Indicator Panel)
1.
Level System Fault Indicator
Indicates a fault in the electronic leveling
system. The fault indicator will flash and
an alarm sound. All functions will default
to creep if the boom is out of transport
mode.
IF THE LEVEL SYSTEM FAULT INDICATOR IS ILLUMINATED, SHUT DOWN THE
MACHINE, RESET THE EMERGENCY STOP, AND RESTART THE MACHINE. IF THE FAULT
PERSISTS, RETURN THE PLATFORM TO THE STOWED POSITION, USING MANUAL LEV-
ELING AS REQUIRED, AND HAVE LEVELING SYSTEM REPAIRED.
2.
AC Generator (If Equipped)
Indicates the generator is in operation.
3.
Platform Overload Indicator (If Equipped)
Indicates the platform has been over-
loaded.
4.
Platform Capacity Indicator
Indicates the maximum platform capacity
selected for the platform.
One of the capacity lights should be on at
all times. Both lights will flash and an
alarm will sound if the platform is out of
the operating envelope for the selected
capacity.
Summary of Contents for 1500SJ
Page 2: ......
Page 28: ...SECTION 1 SAFETY PRECAUTIONS 1 14 JLG Lift 3121261 NOTES ...
Page 68: ...SECTION 3 MACHINE CONTROLS AND INDICATORS 3 24 JLG Lift 3121261 NOTES ...
Page 100: ...SECTION 4 MACHINE OPERATION 4 32 JLG Lift 3121261 NOTES ...
Page 143: ...SECTION 5 LCD DISPLAY PANEL GENERATION 1 2 3121261 JLG Lift 5 43 Figure 5 29 BCS Lamp Screen ...
Page 149: ...SECTION 5 LCD DISPLAY PANEL GENERATION 1 2 3121261 JLG Lift 5 49 Figure 5 34 Swing DTC Screen ...
Page 166: ...SECTION 6 EMERGENCY PROCEDURES 6 4 JLG Lift 3121261 NOTES ...
Page 180: ...SECTION 7 ACCESSORIES 7 14 JLG Lift 3121261 NOTES ...
Page 208: ...SECTION 8 GENERAL SPECIFICATIONS OPERATOR MAINTENANCE 8 28 JLG Lift 3121261 NOTES ...
Page 212: ......
Page 213: ......