SECTION 4 - MACHINE OPERATION
3121261
– JLG Lift –
4-17
4.11
MACHINE SAFETY SYSTEM OVERRIDE (MSSO)(CE
ONLY)
The Machine Safety System Override (MSSO) is
used to override function controls for Emergency
Platform Retrieval only. Refer to Section 6.5,
Machine Safety System Override (MSSO)(CE Only)
for operating procedures.
4.12
SKYGUARD OPERATION
Skyguard is used to provide enhanced control panel protection.
When the SkyGuard sensor is activated, functions that were in
use at the time of actuation will reverse or cutout. The table
below outlines these functions.
Table 4-1. SkyGuard Function Table
Main
Lift
Main
Tele In
Main
Tele Out
Swing
Drive
Forward
Drive
Reverse
Tower
Lift Up
Tower
Lift
Down
Platform
Level
Platform
Rotate
Jib
Lift
Jib
Rotate
Jib
Tele
R
C
R
R
R
C*
R
R
N/A
N/A
C
C
C
N/A
C
R: Indicates reversal is activated
C: Indicates cutout is activated
N/A: Indicates the function does not exist for the model
Summary of Contents for 1500SJ
Page 2: ......
Page 28: ...SECTION 1 SAFETY PRECAUTIONS 1 14 JLG Lift 3121261 NOTES ...
Page 68: ...SECTION 3 MACHINE CONTROLS AND INDICATORS 3 24 JLG Lift 3121261 NOTES ...
Page 100: ...SECTION 4 MACHINE OPERATION 4 32 JLG Lift 3121261 NOTES ...
Page 143: ...SECTION 5 LCD DISPLAY PANEL GENERATION 1 2 3121261 JLG Lift 5 43 Figure 5 29 BCS Lamp Screen ...
Page 149: ...SECTION 5 LCD DISPLAY PANEL GENERATION 1 2 3121261 JLG Lift 5 49 Figure 5 34 Swing DTC Screen ...
Page 166: ...SECTION 6 EMERGENCY PROCEDURES 6 4 JLG Lift 3121261 NOTES ...
Page 180: ...SECTION 7 ACCESSORIES 7 14 JLG Lift 3121261 NOTES ...
Page 208: ...SECTION 8 GENERAL SPECIFICATIONS OPERATOR MAINTENANCE 8 28 JLG Lift 3121261 NOTES ...
Page 212: ......
Page 213: ......