SECTION 1 - GENERAL SPECIFICATIONS
1-2
31215808
1.4
PERFORMANCE DATA
Platform Data
1.5
MACHINE COMPONENT WEIGHTS
1.6
SERIAL NUMBER PLATE LOCATIONS
For machine identification, a serial number plate is affixed to
the machine. The plate is located on the back of the mast, just
above the mast support bracket.
1.7
TORQUE REQUIREMENTS
When maintenance becomes necessary or a fastener has loos-
ened, refer to the applicable Torque Specification chart in this
section of the manual to determine proper torque values for
various size fasteners.
1.8
LUBRICATION
Hydraulic Oil (HO)
Hydraulic oils must have anti-wear qualities at least to API Ser-
vice Classification GL-3, and sufficient chemical stability for
mobile hydraulic system service. JLG Industries, recommends
standard UTTO hydraulic oil, which has an SAE viscosity of
10W-30 and a viscosity index of 152.
For cold weather applications, i.e. when temperatures remain
consistently below +20°F (–7°C) JLG recommends using
hydraulic premium fluid.
Aside from JLG recommendations, it is not advisable to mix
oils of different brands or types, as they may not contain the
same required additives or be of comparable viscosities. If use
of hydraulic oil other than standard UTTO is desired, contact
JLG Industries for proper recommendations.
SPECIFICATION
25AM
30AM
38AM
Occupants:
(Persons allowed in Platform)
Platform Capacity:
ANSI:
(U.S.A, Brazil, Japan, China, Latin America)
CE:
(Europe, Australia)
350 lb
(160 kg)
300 lb
(136 kg)
300 lb
(136 kg)
350 lb
(160 kg)
300 lb
(136 kg)
300 lb
(136 kg)
Platform Height - Mast Fully Extended
- (Ground to Plat-
form Floor):
25 ft.
(7.62 m)
30 ft.
(9.14 m)
38 ft.
(11.58 m)
Platform Working Height
-
(Average Size Person):
31 ft.
(9.4 m)
36 ft.
(11 m)
44 ft.
(13.4 m)
Platform Cycle Performance -
(in seconds) (w/max. rated
load)
Pump - Lift Up:
Lift Down:
62
72
120
32 - 42
32 - 42
45 - 55
MODEL
25AM
30AM
38AM
Platform Weigh
t
:
(Standard Platform)
55 lb (25 kg)
DC Voltage Battery Pack:
(Wet Cell)
70 lb (32 kg)
Table 1-1. Hydraulic Oil Operating Range
HYDRAULIC SYSTEM OPERATING
TEMPERATURE RANGE
SAE VISCOSITYGRADE
+0° F to +180° F (-18° C to -83° C)
10W
+0° F to +210° F (-18° C to +99° C)
10W-20, 10W-30
+50° F to +210° F (+10° C to +99° C)
20W-20